(3-1) Selecting the Standby mode
(3-2) Releasing the Standby mode
Note 2: Commands (1) and (2) can be entered in any order. Also, command (1) is optional.
(4-2) Releasing the Sleep mode
Note 3: Commands (1) and (2) can be entered in any order. Also, command (1) is optional.
(4-1) Selecting the Sleep mode
End of initialization
Normal operation
(Power Save is released and
oscillator circuit is turned ON.)
Command input:
(1) Display on/off control command
• D: Off (Display)
(2) Power save command
• PS: On (Power save)
• O: On (Oscillation)
(3) Power control commands
• P, VF, VC: Off
Standby status
Static display control
commands can be used.
(Note 2)
(Note 2)
End of initialization
Normal operation
(Power Save is released and
oscillator circuit is turned ON.)
Command input:
(1) Display on/off control command
• D: Off (Display)
(2) Power save command
• PS: On (Power save)
• O: Off (Oscillation)
(3) Power control commands
• P, VF, VC: Off
Enter the Sleep mode.
(Note 3)
(Note 3)
Standby mode
Command input:
(1) Display on/off control command
• D: On (Display)
(2) Power save command
• PS: Off (Power save)
• O: On (Oscillation)
Input of electronic volume register
command
Data: (0, 0, 0, 0)
Input of power control commands
P, VF, VC: Off
Input of electronic volume register
command
Data: Appropriate value
Return to normal operation (initial status).
(Note 2)
(Note 2)
Sleep mode
Command input:
(1) Display on/off control command
• D: On (Display)
(2) Power save command
• PS: Off (Power save)
• O: On (Oscillation)
Wait for 20 msec or more.
Input of electronic volume register
command
Data: (0, 0, 0, 0)
Input of power control commands
P, VF, VC: On
Input of electronic volume register
command
Data: Appropriate value
Return to normal operation
(initial status).
(Note 3)