Specifications

8–64 EPSON
SED1240 Series
(2-1) Setting the Standby mode (2-1) Resetting the Standby mode
(3-1) Setting the Sleep mode (3-1) Resetting the Sleep mode
End of initialization
Normal operation
(Power save is cleared and oscillating circuit is on.)
Enters Standby status.
Displays only the static icon
(1) Display on/off control command input
- D : off (display)
(2) Power conrtol command input
- P, VF, VC : off
(3) Power save command input
- PS : on (power save)
- O : on (oscillate)
Standby mode
Wait for 500 microseconds or more.
Returns to normal operation (original state).
(1) Power save command input
-PS : off (power save)
-O : on (oscillate)
(2) Power control command input
-P, VF, VC : on
(3) Display on/off control command input
- D : off (display)
End of initialization
Normal operation
(Power save is cleared and oscillating circuit is on.)
Enters Sleep status.
All displays off
(1) Display on/off control command input
- D : off (display)
(2) Static icon control
- Address : 00H - Data (0, 0, 0, 0, 0)
- Address : 01H - Data (0, 0, 0, 0, 0)
- Address : 02H - Data (0, 0, 0, 0, 0)
- Address : 03H - Data (0, 0, 0, 0, 0)
(3) Power control command input
- P, VF, VC : off
(4) Power save command input
- PS : on (power save)
- O : on (oscillate)
Sleep mode
Wait for 500 microseconds or more.
(1) Power save command input
- PS : off (power save)
- O : on (oscillate)
(2) Power control command input
- P, VF, VC : on
(3) Display on/off control command input
- D : on (display)
(1) Static icon control
- Address : 00H - Data (*, *, *, *, *)
- Address : 01H - Data (*, *, *, *, *)
- Address : 02H - Data (*, *, *, *, *)
- Address : 03H - Data (*, *, *, *, *)
Returns to normal operation (original state).