Specifications

EPSON 9–11
SED1278
SED1278
AC Characteristics
MPU write cycle timing (write to SED1278)
R/W
t
AS
t
WEH
t
AH
t
AH
V
IL1
V
IL1
V
IH1
V
IH1
tcyc
E
V
IL1
t
DS
t
DH
t
rE
t
FE
V
IL1
V
IH1
RS
E
DB0 to DB7
Valid Data
MPU read cycle timing (read from SED1278)
R/W
RS
V
IH1
V
IH1
t
WEH
V
IH1
V
OH1
t
cycE
V
OL1
t
r
E
t
RD
t
DHR
V
IL1
t
fE
t
AH
t
AH
t
AS
V
IL1
E
DB0 to DB7
Valid Data
(VDD = 5.0 V ± 10%, VSS = 0 V, Ta = –20 to 70°C)
Parameter Symbol Condition
Rating
Unit
min max
Enable cycle time tcycE 500 ns
Enable “H” level pulsewidth tWEH 220 ns
Enable rise/fall time trE, tfE —25ns
RS, R/W setup time tAS 40 ns
RS, R/W address hold time tAH 10 ns
Data setup time tDS 60 ns
Write data hold time tDH 10 ns