User manual

X K 3 1 9 0C 602
8
[ AB]
[PL ]
A—selection of printing language
(0: English; 1: Chinese)
B—printing direction
(0: no reverse printing, 1: reverse printing)
Parameter B
is only effective
for micro printer. A
s for
panel-instal
led micro printer,
selecting reverse printing is
easy for checking printing
result.
9
[ AB]
[Auto P]
A—automatic printing
(0: no print, 1: automatic print)
B—automatic data saving
(0: no saving, 1: saving weight, 2
: saving
time and weight) see note 1
If parameter A is set as 1
, the
quantitative scale
will
automatically print the actual
discharge quantity each time
and the catchweigher will
print the weight of material
measured each time.
10
[******]
[Aout_W]
T
he corresponding weight at full
range of analog output
When this weight is reached, the indicator
will output analog value at full range.
T
his value can be larger than
the max. weighing value
, but
the max.
output value is the
corresponding value at max.
weighing. W
hen this value is
smaller than the max.
weighing value
, the full range
of analog output
will remain
unchanged.
11
[******]
[Aout_0]
DA internal code (0-20000
) at zero point
of analog output
(output 4-20mA signal about 12520;
Output 0-5V/0-10V is 0)
T
he zero point of calibration
analog output
of this
parameter can be modified.
12
[******]
[Aout_F]
DA internal code (10000-65535)
at full
range of analog output
(4-20mA output about 62590;
0-5V/0-10V output about 65200)
T
he full range value of
calibration analog output
of this parame
ter can be
modified.
13
[ ABC]
[type ]
Aworking mode of the indicator
(0: additive scale, 1: subtracting scale, 2
:
self-control catchweigher, 3
: external
control catchweigher)
Bparameters number (0-4)
Cweight unit
(0: mg, 1: g, 2: kg, 3: t)
E
xternal control
catchweigher mode: the
indicator w
ill only measure
weight upon being activated
by external control signal;
Self-
control catchweigher:
the indicator
automatically
starts weighing when the
weight is larger than zero
zone value.
14
[ A]
[Print?]
A-whether to print parameter setting
(0: No: 1: Yes)