program step 1. Otherwise stop the action.
13 If there is an Add Signal, go to program step 14.
14 Start the material discharging, add material to the hopper until the
allowed weight is reached and go to program step 15.
15 If the material discharging is started manually, then stop the action.
Otherwise go to program step 16 and the timer will be T6.
16 Timing is over, go to program step 1 to continue the cycle