User manual

X K 3 1 9 0C 602
Chapter 7 Operation Instruction of Batching scale
I. Power on and Zero Setting upon Start up
1. After power is on, the screen will full display 10 seconds and show the instrument type and
software version, then finally enter the weighing status. If the buttonExitis pressed during
automatic checking, it will be ended in advance.
2. If the setting of ‘zero setting upon startup’ is valid, the empty scale weight deviates from zero
and is still in the zero setting scope after startup, the screen will execute zero setting upon startup
automatically; If it is not in the zero setting scope, the screen will show the weight based on the
zero point upon shutting down. Please see the setting of parameter C in parameter 2
of Chapter [SET 1] parameter setting for zero setting scope upon startup.
3. If the ‘zero setting upon startup’ switch is set OFF, the screen will show the weight based on the
zero point upon shutting down after startup. The operation ofZero settingbutton for the first
time will be regarded as the initial zero setting.
II. Manual Zero Setting
If the display value deviates from zero point and is still in the manual zero setting scope
while the light is stable ON, press the buttonZero settingto get the display value back to zero
and zero point lamp will be ON. Please see the setting of parameter B in parameter 2
of Chapter [SET 1] parameter setting for manual zero setting scope.
If it is the net weight status now, press the buttonZero settingto change to gross weight
display status and press buttonZero settingagain to execute zero setting operation.
III. Tare
Under the weighing status, when the display weight is positive and stable, press button [Tare]
to deduct the display weight, which serves as tare weight. Then the current display net weight will
be 0 and the display light for net weight will be ON.
The following operations are mentioned in the chapter parameter setting, it will be described
repeatedly in push-button order, which can help to memorize it.
IV. Setting of Date and Time
[ ABCD]
[0 SEt ]
[ ABCD ]
[0 SEt
]