User manual

X K 3 1 9 0C 602
the auxiliary display of the instrument will show the current program step number in forms of
‘Step**’.
Table 8-2 Description of Program Steps of Self-control Mode
Program
Step
Description
1
If the net weight value is more than upper limit of zero zone, go to
program step 2 and timer will be T0.
2
Timing T0 is over. Start to calculate the average weight and go to
program step 2, timer will be T1.
3
Record the weight data. Timing of T1 is over. Calculate the
average weight at the time interval T1 and go to program step 4
and timer will be T2.
4
Timing T2 is over. Save the weight data and sort it by the weight.
Output the batching signal by channel and timer will be T3.
5
Timing T3 is over. Close the batching signal. If the weight is back
to zero zone, go to program step 1.