User manual

X K 3 1 9 0C 602
Send by
instrument
Pause/Continue
02H Addr K XH XL 03H 02H AK0A 03H
the instrument enters
into pause or running
state
Send by
PC
Accumulate
02H Addr L XH XL 03H 02H AL0D 03H
L
Send by
instrument
Accumulate
02H Addr L XH XL 03H 02H AL0D 03H
Send by
PC
Print
02H Addr M XH XL
03H
02H AM0C 03H
M
Send by
instrument
Print
02H Addr M XH XL
03H
02H AM0C 03H
Send by
PC
Print
accumulation
02H Addr N XH XL 03H 02H AN0F 03H
N
Send by
instrument
Print
accumulation
02H Addr N XH XL 03H 02H AN0F 03H
Send by
PC
Print working
parameter
02H Addr O XH XL 03H 02H AO0E 03H
O
Send by
instrument
Print working
parameter
02H Addr O XH XL 03H 02H AO0E 03H
Send by
PC
Print calibration
parameter
02H Addr P XH XL 03H 02H AP11 03H
P
Send by
instrument
Print calibration
parameter
02H Addr P XH XL 03H 02H AP11 03H
Send by
PC
Read calibration
parameter
02H Addr Q XH XL
03H
02H AQ10 03H
Q
Send by
instrument
Send calibration
parameter
02H Addr Q NN ******
XH XL 03H
……
The instrument returns
to all calibration
parameters. See note 2
for details.
Send by
PC
Read working
parameter
02H Addr R XH XL
03H
02H AR13 03H
R
Send by
instrument
Send working
parameter
02H Addr R NN
****** XH XL 03
……
The instrument returns
to all calibration
parameters. See note 3
for details.
Send by
PC
Read saving
record
02H Addr S NN XH
XL 03H
02H AS0012 03H
See note 4 for details.
S
Send by
instrument
Send saving
record
02H Addr S NN
****** XH XL 03H
……
The instrument returns
to accumulation data or
record all data.
See note 4 for details