User manual

X K 3 1 9 0C 602
Note 4 of Table E-2: NN=00: read accumulated data, NN=01: read all stored data.
Codes of accumulated data of quantitative scale: Tc total times; Tw total weight. Codes of accumulated data
of batching scale: Tc total times; Tw total weight; 1C~5C total times of channel 1 ~ channel 5; 1W~5W total
weight of channel 1~ channel 5.
Format of saved data output:
02H, address, command (S), sequence No. (five bytes), space (1 byte), [time (yy/mm/dd/hh:mm:ss) (if there
is time data only whenSET—1parameter 9B = 2)], weight (7bytes), 0DH, 0AH, 03H.
If there is no data or the data is sent out, return to original command.
Note 5 of Table E-2: Parameter code is same as Note 2. Two ends of data character string are separated by a
space respectively, parameter length is limited within 8 characters, parameter value should be in effective range
specified in the specifications, or unexpected problem may occur. After all data requiring modification are sent, at
last one write command will be sent, which is the command with parameter code WR and without parameter value.
Note 6 of Table E-2: parameter code is same as Note 3, and parameter limitation is same as Note 5. After all
data requiring modification are sent, at last one write command will be sent, which is the command with
parameter code WR and without parameter value.
Note 7 of Table E-2: the parameter is 1 ASCII character 0, 1 or ?, 1 represents entering remote control state,
0 represents exiting remote control state, ? represents inquiring remote control state. After PC has sent the
command of converting to remote control state, if C602 is in stop state, remote control state will be entered; if
C602 is in operation state, this command will be omitted; the returned command parameter is 0.
Note 8 of Table E-2: See Table E-6 for the meaning of NN parameter. Parameter value is represented by 3
digits of integer, indicating 8 digits of binary data. 8 digits of binary data of input and output signal state are
relevant to all signals. See E-7 for the content of signal light state.
Table E-6 Definition of Parameter of Signal Reading State
Parameter code Definition
ST Instrument signal light state
I0 Basic input signal state
I1 Input signal state of the first IO extended module
I2 Input signal state of the second IO extended module
I3 Input signal state of the third IO extended module
I4 Input signal state of the fourth IO extended module
O0 Basic output signal state
O1 Output signal state of the first IO extended module
O2 Output signal state of the second IO extended module
O3 Output signal state of the third IO extended module
O4 Output signal state of the fourth IO extended module
Table E-7 Definition of Character for Signal Light State
Bit B7 B6 B5 B4 B3 B2 B1 B0
Definition Remote
control
Net
weight
Zero
point
Stable Weighing Communication Stop Run
Note 9 of Table E-2: this command is only effective in remote control state, for write output signal. C602 can
execute this command at once after receiving it, and change corresponding IO port output state. Parameter code