User manual

X K 3 1 9 0C 602
There is only English format for parameter print, with explanation as follows:
Content of print Explanation
Set NO. 0
Parameters No., corresponding to SET 1
parameter 13B
Ctrl: 000
Control setting, corresponding to SET 2
parameter 1
Pt : 00010
Preset cycling times, corresponding toSET 2
parameter 2
A1 : 003.000kg
Batching value of material 1, corresponding to
SET
2parameter 3
B1 : 000.500kg
Quick feed lead of material 1, corresponding to
SET
2parameter 4
C1 : 000.020kg
Slow feed lead of material 1corresponding to
SET
2parameter 5
D1 : 000.020kg
Tolerance of material 1, corresponding toSET 2
parameter 6
A2 : 003.000kg
Batching value of material 2, corresponding to
SET
2parameter 7
B2 : 000.500kg
Quick feed lead of material 2, corresponding to
SET
2parameter 8
C2 : 000.020kg
Slow feed lead of material 2, corresponding to
SET
2parameter 9
D2 : 000.020kg
Tolerance of material 2, corresponding toSET 2
parameter 10
0_Zone 000.010kg
Zero area setting, corresponding to SET 2
parameter 11
T0 : 0.2 s
Timing 0, corresponding toSET 2parameter 12
T1 : 0.2 s
Timing 1, corresponding toSET 2parameter 13
T2 : 0.2 s
Timing 2, corresponding toSET 2parameter 14
T3 : 0.2 s
Timing 3, corresponding toSET 2parameter 15
T4 : 0.2 s
Timing 4, corresponding toSET 2parameter 16
T5 : 0.2 s
Timing 5, corresponding toSET 2parameter 17
T6 : 0.2 s
Timing 6, corresponding toSET 2parameter 18
T7 : 0.2 s
Timing 7, corresponding toSET 2parameter 19