Instruction Manual

1
2
3
Self tapping screws
4
Support leg can be
bent in or out.
1. Place box support between electrical box and plaster ring as shown.
2. Attach plaster ring to box as shown.
3. Position offset in box support fully onto edge of stud as shown. Bend
support leg to alternate stud depth as needed.
4. Align notch on box support with box location mark on stud. Mount
assembly to stud using self tapping screw. SMS8 low-profile screw
is recommended.
(Do not feed non-metallic sheathed cables through hole in support leg.)
Model
Number
Description
H23
4" Sq. and 4-11/16" Outlet Boxes to 2-1/2" or
3-5/8" Studs
H4
4" Sq. and 4-11/16" Outlet Boxes to 2-1/2",
3-5/8" or 4" Studs
H6
4" Sq. and 4-11/16" Outlet Boxes to 2-1/2",
3-5/8", 5-1/2" or 6" Studs
TECHNICAL SUPPORT:
www.erico.com
CFS514_B
INSTRUCTION SHEET
1 OF 2
© 2014 ERICO International Corporation.
CADDY® H Series
Electrical Box Bracket
WARNING:
ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at
1.
www.erico.com
and from your ERICO customer service representative.
ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
2.
All instructions must be
completely
followed to ensure proper and safe installation and performance.
3.
Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property
4.
damage, serious bodily injury and death.
Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.
5.
All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
6.
other purpose.
NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified
engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
UL is a registered certification mark of UL LLC
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

Summary of content (2 pages)