User guide

Technical Specification
B.6 AC Supply
This equipment is fitted with dual wide-ranging power supply suitable for supply
voltages of 100-240 V AC -10% +6% at 50/60 Hz nominal.
Table B.14 Supply Specification
Item Specification
Power distribution
system
Type TN ONLY (EN 60950-1 Annex V): Power distribution
system which is directly earthed, the parts of the equipment
required to be earth being connected by Protective Earthing
Conductors. This equipment must NOT be used with
single-phase three-wire and PE, TT or IT Type Power
distribution systems.
Connection to
supply
Pluggable Equipment Type A (EN 60950-1 para 1.2.5):
Equipment which is intended for connection to the building
power supply wiring via a non-industrial plug and socket-outlet
or a non-industrial appliance Coupler or both. Correct mains
polarity must always be observed. Do not use reversible plugs
with this equipment
Class of equipment Class I Equipment (EN 60950-1 para 1.2.4): electric shock
protection by basic insulation and protective earth
Rated voltage
[Operating voltage]
100-240 V AC (single phase)
Rated frequency
[Operating freq]
50/60 Hz [48-63 Hz]
Voltage selection Wide-ranging
Rated current 4.0 - 2.0 A, 100 – 240 V AC
Input connector AC power input filter with CEE 22/IEC320 plug
Fuse Fuse in live conductor in power input filter at rear of unit.
Fuse type
Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating 5 A 250 V T HBC
Power
consumption
80 W (NO options fitted)
2/1553-FGC 101 1014 Uen B
B-12