User guide

Conditional Access
Figure D.8 Static Parameter Editor
Table D.4 Configuring the MX8400 Multiplexer Static Parameters (continued)
Step Action Result Comments
5
Set the CA Floating Port
Address
This defines the IP
address to which the
EMMG will try to
connect
The CA Floating Port is the network port
which will be externally visible
Set the CA-related
parameters:
Define the EMMG TCP
Port
Defines the EMMG
connection and
whether it will
connect using TCP
only or use both
TCP and UDP.
This is the EMMG port the multiplexer must
listen on
This information is supplied by the CA
vendor.
Define the EMMG UDP
Port
Leave the EMMG UDP port set to zero
unless the CA vendor specifies otherwise.
6
Define the PDG Port
If PDG components are not used, set this to
zero
2/1553-FGC 101 1014 Uen B
D-15