User guide

Installing and Powering Up
Table 2.8 Static Parameters - Editing Data Port IO Mode
Name Description
Input Mode
Data input port mode
Bidirectional/Independent/Autonomous/Autonomous
Revert/Bidirectional
Revert.
Input Revert Input Revert Wait Time (in seconds)
Output Mode
Data output port mode
Indipendent/Autonomous/Mirrored/Autonomous Revert
Output Revert Output Revert Wait Time (in seconds)
2.8.3 Reported Faults
Table 2.9 describes the faults associated with the network.
Table 2.9 Ethernet Input Reported Faults
Fault Level
Network input link lost Major
All network input links lost Critical
Port CRC error Warning
Port IP checksum error Warning
Port UDP checksum error Warning
Network output link lost Major
All network output links lost Critical
Configured input port not in use Warning
Configured output port not in use Warning
Network buffers running low Warning
Network buffers run out Major
CA network and control network are on the same
subnet CA Network has been disabled
Warning
CA has been incorrectly configured to use both CA
and Control networks. Check CA Ethernet static
parameters
Warning
Table 2.10 describes the reported faults associated with the Ethernet Input.
2/1553-FGC 101 1014 Uen B
2-21