User guide

Installing and Powering Up
2.12 Ethernet Control 1 & 2
2.12.1 Overview
2.12.1.1 Functional Description
The Ethernet control ports are used to connect the MX8400
Multiplexer to nCompass Control. Depending on the configuration,
both connectors and the floating address have different IP
addresses. However, if required, the floating address can share
the address of one of the connectors. The active control port
switches from ETHERNET 1, when it looses the link (e.g. carrier)
to ETHERNET 2 (only if it has a link). Refer to Chapter 3 for IP
Address information.
Note: The MX8400 can be controlled using a single control connection.
Table 2.19 Ethernet Control 1 and 2 Connectors
-1---------8-
Item Specification
Connector type RJ-45
Connector designation
ETHERNET 1
ETHERNET 2
Pin:
(Unused pins not
connected)
Pin 1 Tx Out (+)
Pin 2 Tx Out (-)
Pin 3 Rx In (+)
Pin 6 Rx In (-)
2.12.1.2 Indicators
Each Ethernet Control connector has associated indicators which indicate the
Activity and Speed of the connection. Table 2.20 describes the meaning of the
indication states.
Table 2.20 Ethernet Control 1 and 2 Interface Indicators
State Indication Comment
Left Indicator (as viewed from the connector side):
Off No active link
Green Full duplex link present Flashing for activity
Yellow Half duplex link present Flashing for activity
Right Indicator (as viewed from the connector side):
Off 10 Mbps
Green 100 Mbps
2/1553-FGC 101 1014 Uen B
2-27