4.8 Setup ASI Monitoring for Each Output Transport Stream
4.8.1 Overview
Each MX8400 Multiplexer has four ASI output ports which, for example, can be used
to simultaneously monitor up to four IP transport streams. It is possible to configure
an ASI output as a monitoring output to enable the user to verify the IP output. The
block diagram in Figure 4.3 has the same configuration as Figure 4.1 to illustrate the
process.
Figure 4.3 ASI Monitoring for each Multiplexer Output Transport Stream
MX8400 Multiplexer
IP Port
ASI Port
Main Output: TS1
Monitoring Output: TS2
4.8.2 Setting up the Monitoring
4.8.2.1 Procedure Summary
This process has three steps:
1. Adding secondary output devices to the Physical Map.
2. Adding a secondary output to the transport stream using nCC Profile Manager
3. Connecting the Multiplexer output to the Monitoring output
4.8.2.2 Setting up a Secondary Output
The steps shown in Table 4.11 show how to set up a Secondary output.
Table 4.11 Setting Up a Secondary Output
Step Action Result Comments
1
In nCompass, Equipment
Setup, right click on a blank
area in the Physical Map
Displays a context-sensitive
menu list
2
Select Add device, Output,
Generic Output
Displays the Output dialog
box
3
Enter the details as required.
Device Label: type a unique
label for the device
2/1553-FGC 101 1014 Uen B