User guide

Operating the Multiplexer using nCompass Control
4.8.2.3 Set up a Secondary Output for the Transport Stream
The next step is to set up a secondary output for the transport stream. This cannot
go over the same physical port. In this configuration, the secondary output is
required to provide the feed to the Monitoring device. This has the same content as
that supplied as the primary output.
If required, more than one secondary output can be added for a single transport
stream.
Table 4.12 Setting Up a Multiplexer Secondary Output
Step Action Result Comments
1
In nCompass, Profile Manager, right
click on the required Transport
Stream
Displays the Transport
Stream tabbed page
2
Select Secondary Outputs
Displays the Multiple
Outputs dialog box
3
Select Add/Remove
Displays a list of Available
and Selected outputs
4
Use the Add button to select the
required Transport Streams
As each stream is selected, it
is added to the Selected
Outputs List.
Only outputs that can be
routed should populate
this list.
4.9 Set up PSI/SI Remultiplexing
4.9.1 Overview
This configuration removes user selected PSI/SI generated by nCompass Control
and the MX8400 Multiplexer and allows the operator to create a Private Data stream
with PSI/SI from an incoming transport stream
Figure 4.4 PSI/SI Remultiplexing
MX8400
Multiplexer
Transport Stream containing
selected PSI/SI from remote T
in addition to any required from
Local generation
S
TS OUT
REMOTE TS
LOCAL TSs
Remote sourced
PSI/SI
PSI/SI
Subs
tit
u
ti
o
n
PSI/SI
Extraction
Local PSI/SI
Generation
2/1553-FGC 101 1014 Uen B
4-15