User guide

Operating the Multiplexer using nCompass Control
The process has two steps:
1. Use the nCC Profile Manager to deselect the required PSI/SI to be generated by
nCompass Control and the MX8400 Multiplexer
2. Configure a Private Data stream to carry PSI/SI data from an incoming
Transport Stream.
The process is described in the following tables.
4.9.2 Deselect the PSI/SI
Table 4.13 Setting Up PSI/SI Remux (Selecting the PSI/SI Tables)
Step Action Result Comments
1
In nCompass Control, Profile
Manager, right click the Transport
Stream icon
2
Select the PSI/SI tab and deselect the
PSI/SI tables to be remuxed and set
the Table repetition intervals for the
remainder.
Indicates the tables to be
extracted from the
incoming transport stream
4.9.3 Adding the Private Data Stream
A Private Data stream is a way of remultiplexing an incoming PID. The PID exists at
the transport stream level then it is not automatically referenced in the PMT. The
process for adding a private data stream is described in Table 4.14.
Table 4.14 Setting Up PSI/SI Remultiplexing (Adding the Private Data Stream)
Step Action Result Comments
1
In nCompass Control, Profile
Manager, right click the Transport
Stream icon
Displays a context-
sensitive menu list
Label:
Enter a unique name for the
Private Data Stream
Bit rate:
Enter the required bit rate
(this is the peak component
bit rate)
Input:
Select the incoming Transport
Stream from the presented
list
Input PID: Enter the incoming PID
2
Select Add Private Stream and edit
the appropriate options
(As an example, we are using the SDT
table from the incoming TS, which will
have an outgoing PID of 17 – part of
the DVB specification)
Output PID: 17 Enter the output PID
2/1553-FGC 101 1014 Uen B