10.1 Installing the Flue Terminal NZ ONLY
Cut the flue termination to the height specified on the attached “Flue
position” diagrams and leave a vertical offset of 20 - 30mm between
the inner and outer as shown. Slide the flue liner sleeve over the
liner and push it down about 150mm out of the way. Fit the flue
spacer bracket between the flue and flue liner.
Cut & bend an 80mm by 100mm flap and bend
towards the inner flue as shown below.
Fit cowl and drill trough the flap, flue and
cowl stem. Using approximately a 1"
stainless steel self tapping screw fix the
cowl in place.
Slide the liner sleeve piece up under the cowl until it hits the flue spacer
bracket. Around the bottom of the sleeve drill and rivet in three places.