9.0 Installing the Flue System NZ ONLY:
Non-Masonry Timber Frame Cavity:
The heater must be flued to the outside via a 100mm diameter stainless steel flue that is
covered by a 150mm diameter liner. This must be installed in accordance with the
requirements of AS5601 / NZ5261.
The minimum flue length = 3.6m vertical height
It is important to check that you have all the necessary flue parts before beginning your
installation.
We recommend that a standard timber flue installation should include the following
components:
2 x 150 x
1200mm
Galv Flue Liner
3 x 100 x
1200mm Flue
1 x 150 x
1040mm
Galv Flue Liner
1 x 100mm Clamping
Flue Sleeve
2 x Flue Liner
Spacer Bracket
1 x Flue Cowl
3 x Spider
Bracket
1 x 180mm Flue
Sleeve
Angle 50x50x900 Flue
Bracing
1 x Flue Liner
Joiner