User's Manual

6 Irideon FPZ
Connect Canopy Wiring (DMX variant)
Cable preparation instructions for DMX termination are included in the
termination kits, and are also available for free download at etcconnect.com.
1: Remove the adhesive tape or fasteners securing the mounting plate to
the fixture to free the mounting plate from the canopy enclosure.
2: Are you flush-mounting the fixture or surface-mounting the fixture?
Flush-mounting: Continue to step 3.
Surface-mounting:
Position the cover
plate on top of the
mounting plate
before wiring the
fixture. The cover
plate is required
when the interior of the canopy enclosure could be exposed after
installation with only the mounting plate (the mounting surface is
smaller than the canopy enclosure).
3: Terminate DMX/RDM input from the
control source to the backbox.
If using Belden 9729:
a: See the
DMX Cable Preparation
for Screw Termination Setup
Guide
for instructions to prepare
and terminate Belden 9729 for
DMX input cable to the screw
terminal connector.
b: Install the screw terminal
connector with wires terminated
to the DMX/RDM Input receptacle
on the termination board.
WARNING:
RISK OF ELECTRIC SHOCK! Install the cover plate as
directed below for installations where the interior of the
canopy enclosure could be exposed after installation
with only the mounting plate. For example, install the
cover plate when installing to a surface-mount backbox.
Mounting plate
Cover plate
(if needed for
surface-mounting)
From a DMX/RDM source
Data – (Black)
Data + (Red)
Belden 9729 (or equivalent) wire
termination to screw connector
4 to 8 = n/c
COM