User's Manual

14 Irideon FPZ
Install Portable
Fixture on Unistrut
Track
You can install the portable
fixture on Unistrut track using
the Irideon FPZ Unistrut Kit
(7191K1000).
1: Insert the spacer into
the driver box through
the hole in the top of
the yoke.
2: Use the yoke bolt and
washers to fasten the
fixture to the Unistrut
track.
Within the EU, use an
M12 bolt and
appropriate washers in
place of the provided
kit hardware.
Connect Cables to Portable Fixture
1: Connect RJ45 data cables to the top of the driver box, one for data in
and one for data thru (in either position), as needed.
To order RJ45-to-female XLR adapter, use part number W6538.
To order RJ45-to-male XLR adapter, use part number W6539.
2: Connect the fixture to the power source.
Note:
The Irideon FPZ is not self-terminating. You must
terminate the last fixture in line with a 120 Ohm
resistor. Please contact your ETC customer service
representative to purchase part number N4086.
No more than 32 DMX devices can be daisy-chained
together on a single run. For runs of fixtures totaling
more than 32 DMX devices, use a DMX splitter to split
the DMX runs.
When using DMX over Cat5, use Cat5e or better. Cable
distance must not exceed 300 m (1000 ft).
The Irideon FPZ cannot be controlled via network
protocols and should not be connected to a system
network.
Washers
Yoke bolt
Spacer