User's Manual

4 Irideon FPZ
Basic Assembly
Installation
Install Track-
Mounted Fixture
1: Insert the DataTrack
adapter into the track.
The adapter only fits into
the track one way with
the tabs nesting into the
track’s groove.
2: Rotate the locking
mechanisms to lock the
adapter into place.
3: Use the circuit selection
lock to select the circuit.
The desired circuit
number should point toward the center of the adapter.
WARNING:
When using the circuit selection lock, ensure that the
selected circuit is a constant power circuit. Dialing into a
dimmable circuit may cause fixture damage that will void
the ETC warranty.
Yoke
Integrated media
holder
Shutters x4
Beam zoom and
focus knobs
Pattern holder
slot
(Illustration shows fixture body only)
Circuit
selection lock
Locking