Instructions

9
Car mode
Charging programme for 12 V batteries from 14 Ah to 120 Ah, temperatures above 0°C
Charge current: 4 A maximum
charge voltage: 14.6 V
Car winter mode
Charging programme for 12V batteries from 14 Ah to 120 Ah, temperatures below 0°C
Charge current: 4 A maximum
charge voltage: 1 4.8 V
Battery maintenance charge mode
As soon as the battery is fully charged, the charger switches automatically over to battery maintenance charge
mode. This is indicated appropriately on the display.
Error messages
Error message in 6 V – mode, if a battery is connected with less than 5.5 V ± 0.2 or the voltage is still lower than
6 V after 4 hours of charging time.
Display of error after faulty connection (wrong poles), short-circuit, selection of an incorrect charging programme
or overheating.
EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal, Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
info@eal-vertrieb.com
www.eal-vertrieb.com
9. Contact information
6.3 Removing the charger
Caution: First pull the plug out of the socket and observe the sequence for disconnection. This prevents sparks from
forming. Since charging generates a detonating gas, this is particularly important for the sake of your safety.
Disconnect the charger from the mains power supply.
Then disconnect the black callipers (minus). Then remove the battery callipers from the plus pole of the battery (red callipers).
Allow the battery to cool and ll the cells with distilled water to the lling level named by the battery manufacturer. Close the
battery cells using the caps.
8. Notes regarding environmental protection
The packaging is made up of environmentally friendly materials which may be disposed of via your local recycling
points. Do not put electrical devices into the household waste. Electronic and electrical devices must be collected sepa-
rately and sent for environmentally friendly recycling. Contact your community or town administration for information
regarding the disposal of electrics.
7. Maintenance and care
7.1 Maintenance
Clean the pole callipers every time the charging procedure is completed. Remove all splashed battery acid from the pole callipers
to prevent corrosion. Clean the device carefully with a dry cloth. Do not use liquids or chemical cleaning agents. Never submerge
the device in liquids. Never allow liquid to ow over the device.
Before storing the device, roll up the cables properly using the designated hook in order to prevent damages to the cables and
device. Store the device in a clean and dry place.
If used correctly, the device is maintenance-free.
7.2 Care
Motorbike winter mode
Charging programme for 12 V batteries from 1.2 Ah to 14 Ah, temperatures below 0°C
Charge current: 2 A maximum
charge voltage: 14.8 V