Glás Non Boiler Insert Installation & Operating Instructions
Table of content 1. 2. 3. 4. 5. Page no: Technical data. . . . . . . . . . . . . . . . . . . 1/2 General Information . . . . . . . . . . . . . . . . . 3/6 Installation Instructions. . . . . . . . . . . . . . . . 7/8 Operating Instruction. . . . . . . . . . . . . . . . . 9 Exploded View/ Parts Listing. . . . . . . . . . . . . . .
Installation introduction with Technical data Installation of a Pierce Stove must be in according to local codes and regulations in each country. Installers must observe all local regulations, including those which refer to national and European standards when installing the product. All Pierce Stoves are accompanied by Both an installation manual with technical data and a manual on general use and maintenance. Only after a qualified inspector inspects an installation, it can be used.
GENERAL INFORMATION: Before installation of your Pierce Stove these instructions should be read carefully to fully understand the controls of your new stove. Keep these instructions for future reference. Due care should be taken when unpacking and installing a Pierce Stove as not to cause damage to your new stove or its surroundings. Check all components are present and functioning before installation occurs.
DISTANCE TO COMBUSTIBLES Pierce Stove insert stoves operate at high temperatures and are designed for installation into an existing fireplace. For safe operation of your Pierce Stove there are minimum distances to combustible materials, including wood and Plaster board, that must be adhered to at all times.
CHIMNEY FIRE It is unlikely you will ever experience a chimney fire if your stove is installed and operated correctly as per the operation instructions. In the unlikely event of a chimney fire close the primary air and secondary air controls immediately, evacuate the building and call the Fire Service. Do not re-enter the building until you have been advised by the Fire service that it is safe to do so.
FAULT FINDING INSTRUCTIONS Problem Fire difficult to start Probable Cause Wood green, too damp or poor quality Logs are too big Fire goes out Air starvation Insufficient draught Action -Use the recommended fuel. -To light the fire, use small, very dry kindling. To maintain the fire, use split logs. -Open primary air and secondary air -Check that the flue is not obstructed, sweep it if necessary Seek specialist advice. -Ensure that the primary air is closed. Partially close secondary air.
INSTALLATION INSTRUCTIONS: Step 1 Open the stove door and remove all loose packed parts, ashpan, tools and accessories. Step 2 Disassemble the internal parts in the following order. 1. Fire Fence 2. Left and Right Side Castings 3. Loose Top Baffle 4. Grate (Riddling bar will need to be removed also) 5. Back Wall 6. Grate Support 1. Fire Fence 2. Side Castings 3. Loose Baffle 4. Grate 5. Back wall 6. Grate Support 2. Side castings 3. Loose Baffle 1. Fire Fence 6. Grate support 5. Back Wall 4.
Step 6 Lift the still disassembled stove into the convection chamber approximately 50mm, lift the front edge to prevent damage to the hearth then slide it gently home to its final position . Step 7 The flue liner can now be fixed to the spigot (part 13 in parts listing) with the fixings provided and sealed according to the manufactures instructions. Step 8 Secure the stove to the convection chamber with the 2no M6 bolts removed in step 3. Before fully tightening push the stove against the fireplace.
OPERATING INSTRUCTIONS: + - - + PRIMARY AIR CONTROL SLIDER VALVE The primary air control slider is positioned underneath the ashpan door (see diagram above left). This slider controls the intake of primary air underneath the grate, slide to the right to increase the rate of burn and to the left to decrease the rate of burn. This slider should be fully open (to the right) when lighting the stove.
GLAS INSERT STOVE EXPLODED VIEW 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Fire Fence PS10120 Ash Baffle PS10162 Ashpan Door PS10108 Fire door PS10107 Front Frame PS10103 Top Baffle I1141 Right Baffle I1113 Left Baffle I1112 Moving Grate I1115 Grate Frame I1114 Back Baffle I1111 Air Wash Cover I1109 Spigot125 (2) Ash Pan Handle CA0105A Hinge A CA1604 Hinge B CA1603 Hinge Axia CA0614 16. Blanking Plate CA1102-B 17. Holder CAWK0105 18. Convection Chamber CAWK01 19. Axial Fiber 20.
Unit 2 Whitemill Industrial Estate Wexford Co Wexford www.piercestoves.ie Email: info@piercestoves.