Specifications

19
11.4 PRESET SPEEDS AND SPEED POT (WITH TWO-WIRE START/STOP CONTROL)
SPEED
POT
RUN
SIGNAL COMMON
0-10 VDC
TB-13A FUNCTION SELECT
(PRESET SPEED #1)
TB-13B FUNCTION SELECT
(PRESET SPEED #2)
TB-13E FUNCTION SELECT
(PRESET SPEED #3)
DIGITAL INPUT REFER-
MAINTAINED
RUN/STOP
CONTACT
1
2
5 6 11 13A 13B 2513E
SPEED POT POWER SUPPLY
16 17
FORM A
RELAY
NOTE:
For preset speed control, all or some of the TB-13 terminals must be
programmed as preset speed selects. If only two or three preset speeds
are required, only two of the TB-13 terminals must be used. Refer to the
table in the description of Parameters 31-37 in Section 15.0.
Program the PRESET SPEEDS (Parameters 31-37) to the desired
values.
If speed pot control is desired when none of the preset speeds are selected
(all preset speed selects are open to TB-11), set STANDARD SPEED
SOURCE (Parameter 05) to 0-10 VDC (03).
SM01J-e2.indd 19SM01J-e2.indd 19 2/6/2007 10:47:38 AM2/6/2007 10:47:38 AM