There must never hang a mirrorball or other load at the safety eyelet. Loads must only be hanged at the
quick link of the installation eyelet at the motor axle. If a mirrorball hangs for any reason at the safety eyelet,
the motor must be taken out of operation immediately and the mirrorball must be uninstalled. The whole
installation has to be checked for defects by an expert.
Make sure that the rotation of the mirrorball is never slowed down or stopped by decoration material etc.
Make sure that no side forces can impact on the installation.
Make sure that the mirrorball cannot be moved by air streams. The mirrorball and the motor must be installed
and operated absolutely swivel free.
Please check in regular intervals, if the installation material (e. g. key ring, shackles or screw-on chain links)
or chain links have been deformed. Uninstall the mirrorball immediately in such a case.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
DANGERTOLIFE!
Beforetakingintooperationforthefirsttime,theinstallationhastobeapprovedbyanexpert!