Service manual

a. Remove the four (4) Phillips screws that
secure the water inlet filter housing to the
unit. See picture below for location of
screws. Once screws are removed reach
into the unit and pull up and out on the
flow control assembly to remove it from
the appliance. Inspect o-ring for damage.
b. Disconnect wiring harness from assembly
and remove the water flow control
assembly from the unit.
IGE - 4. Removal of Ignition Module:
CAUTION
120 volt potential exposure. Isolate the appliance
and reconfirm power has been disconnected
using a multimeter.
a. Remove one (1) Phillips screw that secures
the sparker module to the unit casing.
b. Disconnect high tension lead and
connector.
IGE - 5. Removal of the Combustion Fan:
CAUTION
120 volt potential exposure. Isolate the appliance
and reconfirm power has been disconnected
using a multimeter.
a. Disconnect wiring harness from fan motor.
b. Remove the (2) Phillips screws that secure
the combustion fan motor to the fan
housing. Pull the fan motor assembly
towards yourself to remove it.
IGE - 6. Removal of the Water Temperature
Thermistor:
CAUTION
120 volt potential exposure. Isolate the appliance
and reconfirm power has been disconnected
using a multimeter.
a. Remove the two (2) Phillips screws that
secure the thermistor in place to remove
the water outlet temperature thermistor.
48