Service manual

IGE - 7. Removal of Transformer:
CAUTION
120 volt potential exposure. Isolate the appliance
and reconfirm power has been disconnected
using a multimeter.
a. Remove the combustion fan motor
assembly as described in section 5-a,b.
b. Remove the two (2) Phillips screws to
release the transformer.
c. Disconnect wiring harness connectors to
transformer and pull out towards you.
IGE - 8. Removal of Burner Manifold and the
Burner:
CAUTION
120 volt potential exposure. Isolate the appliance
and reconfirm power has been disconnected
using a multimeter.
a. To remove the burner manifold, remove
(6) Phillip screws around the burner plate
as shown in the upper right picture.
b. Remove the (3) Phillip screws at the gas
valve assembly.
c. Grip the burner manifold and remove it
from the unit.
d. To remove the burner assembly remove
(8) Phillip screws around the sight glass
panel. Remove this panel.
e. Locate the (2) Phillip screws inside the
burner chamber that hold the burner
assembly in place. Remove these two
screws, grip the burner assembly and slide
it out of the combustion housing.
f. If you need to remove each burner from
this housing remove the (2) Phillip screws
on each side of the burner, as shown
below.
49