Assembly and Dressing Instruction

WARNINGS:
Turn off power (unplug from the wall outlet) before replacing the bulb(s), making
sure the bulb(s) had sufficient time to cool down. DO NOT subject the lamp to any
shock while lit as shattering of lamp may result.
TO ASSEMBLE:
1. Carefully remove all parts from the box and remove all plastic covering.
2. Turn off power to the junction box where the pendant will be installed.
For Hanging:
3. Hook the chain (F) to top loop (G).
4. Feed wire through chain (F) and mounting loop (E).
5. Remove mounting plate (A) from fixture base (C) by unscrewing cap nuts (D)
6. Attach mounting plate (A) to ceiling outlet box and secure with mounting screws
(B) provided.
7. Attach chain (F) with light fixture to mounting loop (E) at desired height.
8. Attach the fixture ground wire to the ground wire from the outlet box (usually
green or bare wire) with a plastic wire connector and wrap the connection with
electrical tape.
9. Connect the hot wire (smooth wire) to the hot outlet box wire (usually black)
with a plastic wire connector and wrap the connection with electrical tape.
10. Connect the neutral wire (ridges molded wire) to the neutral outlet wire (usually
white) with a plastic wire connector and wrap the connection with electrical
tape.
11. Tuck these wire connections neatly into the ceiling outlet box.
12. Attach fixture base (C) to affixed mounting plate (A), letting the rod on mounting
plate (A) pass through the holes on fixture base (C) and secure with cap nuts
(D).
13. Attach side opening of shade spider (J) to threaded section and secure with
threaded ring (H)
14. Hook the crystal drop (K) to the bottom of light fixture.
15. Insert the recommended 60-watt Type B bulbs (not included) into the threaded
sockets.
16. Restore power to the junction box and test the pendant fixture.
17. Assembly is complete.
For Ceiling:
3. Remove chain (F), attach top loop (G) to mounting loop (E).
4. Feed wire through mounting loop (E).
5. Follow steps 4-5 of For Hangingassembly.
6. Follow steps 7-16 of For Hangingassembly.
CARE INSTRUCTIONS:
To clean, use a soft cloth only. DO NOT use any chemical or abrasive cleaners.
For Hanging
For Ceiling
PARTS ENCLUDED
(A) Mounting plate
(B) Mounting screws
(C) Fixture base
(D) Cap nuts
(E) Mounting loop
(F) Chain
(G) Top loop
(H) Threaded ring
(J) Shade
(K) Crystal drop 2"
Electrical Danger
Turn Power Off
All electrical componets must be
installed by a licensed electrician
in accordance with the National
Electric Code and the appropriate
local electrical codes.
L
E
R
T
You will need 4 - Cand. Bulb
60 Watts Max
Bulb not included.