Instructions / Assembly

20
Evo, Inc., 20560 SW 115th Ave., Tualatin, OR 97062 USA
Phone 503.626.1802 | Fax 503.213.5869 | www.evoamerica.com | support@evoamerica.com
WARNING
WARNING
WARNING
DANGER
Checking For Gas Leaks
Note: All factory-made connections have been
thoroughly checked for gas leaks. The burners and
ignition system has been ame tested. As a safety
precaution, we recommend you recheck all ttings
for leaks before using your Evo grill. Shipping and
handling may loosen or damage a gas tting.
Installing Natural Gas Connection To Grill
TO PERFORM A LEAK CHECK YOU WILL NEED A
SOLUTION OF SOAP AND WATER AND A BRUSH OR
RAG TO WET ALL GAS CONNECTIONS.
1. Slide back the collar of the quick disconnect. Push the
male tting of the hose into the quick disconnect and
maintain pressure while releasing the collar.
3. If tting does not engage and lock, repeat procedure.
Gas will not ow unless the quick disconnect is properly
engaged.
4. Turn on gas supply and check for leaks by wetting the
connections with the soap and water solution and watch-
ing for bubbles. If bubbles appear, or if a bubble grows,
there is a leak.
Note: Since some leak test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
CHECK THE FOLLOWING CONNECTIONS:
1. HOSE TO MANIFOLD CONNECTION
WARNING: If there is a leak where the hose con-
nects to the manifold then retighten the tting with
a wrench and recheck for leaks with soap and water.
If leak continues after retightening the tting, tun off
gas. DO NOT OPERATE GRILL. Contact your local
dealer or Evo Customer Service using the contact
information provided with your manual.
2. VALVES TO MANIFOLD CONNECTIONS.
3. HOSE TO QUICK DISCONNECT CONNECTION.
Do not use an open ame to check for gas leaks. Be
sure that are no sparks or open ames in the area while
you check for gas leaks. Flames and sparks will result
in a re or explosion which can cause serious bodily
injury or death and damage to property.
You should check for gas leaks every time you discon-
nect and reconnect a gas tting.
Perform leak checks even if your grill was dealer or
store assembled.
Do not ignite burners when leak testing.
Gas Coupling Connected
Gas Coupling Disconnected