LIGHTING STANDING PILOT BURNERS
To Light The Inner and Outer Standing Pilot Burners:
STEP 1: The external gas shut-off valve must be in the ON position.
STEP 2: Press the Ignition Button and simultaneously press the Inner Burner Pilot Light Button. It may
be necessary to keep the pilot light button depressed for several minutes if air in the gas line was not
bled before installation. Check to see if the gas pilot light is burning by visually inspecting through the
Flame Viewing Portals for the presence of a fl ame. Once a fl ame is present, stop pressing the Ignition
Button and continue pressing the pilot light button for an additional 30 seconds to 1 minute to allow the
Thermocouple to become hot and the Pilot Safety Valve to open.
STEP 3: Once a steady fl ame is witnessed, release the Inner Burner Pilot Light Button and confi rm the
pilot light continues to burn. If the pilot light fails or extinguishes, then repeat Step 1. The most common
reason for the pilot light sequence to fail is the pilot light button is not held long enough to heat the
thermocouple, or there’s an excess amount of air in the inlet gas line created during installation. With
the pilot safety valve open, full functionality to the inner and outer burners is now available.
STEP 4: Repeat steps 1 and 2 for the Outer Burner Pilot Light. With both the inner and outer pilot light
burners lit and continuously burning, full functionality to the inner and outer main tube burners is now
available.