RECOGNIZING ABNORMAL GAS OPERATION
Any of the following are considered to be abnormal operation and may require servicing:
Excessive yellow tipping of the burner fl ame (See diagram above).
Sooting up of cooking utensils.
Burners not igniting properly.
Burners failing to remain alight.
Gas valves, which are diffi cult to turn.
In case the appliance fails to operate correctly, contact the authorized service provider in your
area.
Right
Flame
Wrong
Flame
Dark Blue
Dark Blue
Light Blue
Light Blue
Yellow Tip
Excessive
Yellow Tipping
Remove the bottom
‘crescent-shaped’ access
panel just under the
front control panel to
access burner venturis, or
alternatively remove the
cooking surface and drip
pan to access the valve
cover located just above the
center control knob.
Checking Venturi Tubes:
A clogged venturi tube due to accumulated debris or lint
may cause improper burner performance and diffi culty
lighting your grill.
To check your venturi tubes:
Remove the bottom ‘crescent-shaped’ access panel just
under the front control panel to access burner venturis,
or alternatively remove the cooking surface and drip pan
to access the valve cover located just above the center
control knob.
Remove the cover and inspect the venturi for debris or
lint accumulation.
Compressed air is the best method for removing these
obstructions.