EXCELL PRECISION CO., LTD.
EXCELL PRECISION CO., LTD. Preparation before Operation 1. Avoid operating the scale in the locations where there is too much temperature changes and air flow, for example, the place under sunlight or air condition. 2. Use the independent power socket to avoid the interrupt of other electronic product. 3. When turning on the scale, do not place any object on the platter. 4. When operating the scale, place the object on the center of the platter.
EXCELL PRECISION CO., LTD. Keyboard Description “UNITS” ⇒ Press the key to select the weighing unit “kg” or “lb.” ”ESC” ⇒ Return function. 1. UNITS ESC 2. PRESET 3. M+ 4. TARE/← 5. PRETARE 6. RECALL 7. CE 8. ZERO/→ : ”ZERO” ⇒ to re-zero weight value; ”→”⇒ to move the cursor rightward. PRINT “PRINT” ⇒ printing. ENTER “ENTER” ⇒ confirmation key. 9. : : Preset function for weight. Accumulation function for weight. : ”TARE” ⇒ tare function; ”←” ⇒ to move the cursor leftward.
EXCELL PRECISION CO., LTD. Function & Operation Backlight Function Press BL/↑ to select 3 backlight modes in cycle: . . , . , ⇒ Auto backlight mode. When the weight is more than 10d, or . pressing keys, the backlight will light up. After re-zeroing (the weight less than 10d) for 5 seconds, the backlight will be off. . ⇒ Backlight always lights up. . ⇒ Backlight off. Weighing Function (1). Unit Selection 1. After turning on the scale, press UNITS display indications “kg” or “lb”.
EXCELL PRECISION CO., LTD. Example: “Lower Limit” Presetting (lower limit >10d, d=division) ex.: lower limit = 20kg. Press PRESET key, the screen displaysï ð Press ZERO/→ once, the screen displays ï Press BL/↑ ï twice, the screen displays Meanwhile, if pressing ENTER . ð ð . . key, the screen will display “0” instead of ” ”. “Upper Limit” Presetting (upper limit ≥ lower limit) ex.: upper limit = 25 kg. Press ENTER Press ZERO/→ Press BL/↑ Press ZERO/→ Press ï ð ð ENTER .
EXCELL PRECISION CO., LTD. 4 Single Point Presetting Lower limit only Method (I) After finished presetting lower limit, the screen displaysï PRESET once again. If the screen displays ð . . Press , the “single point . presetting” is completed. Method (II) After finished presetting lower limit, upper limit and buzzer, press When the screen displaysï ð . , press RECALL this time the screen displays presetting upper limit, press displays PRESET CE once. twice again. At once.
EXCELL PRECISION CO., LTD. Note 1 Χ Χ A B A ⇒ 0 = Buzzer beeps when being stable; LCD indication lights up. 1 = Buzzer beeps when being stable; LCD indication lights up without stable determination. 2 = Buzzer beeps and LCD indication lights up without stable determination. B ⇒ 0 = No buzzer beep. 1 = When it’s OK (the value higher than lower limit and lower than upper limit,) the buzzer beeps. 2 = When the value is lower than or equal with lower limit, or higher than upper limit, the buzzer beeps.
EXCELL PRECISION CO., LTD. 4 LCD Indication: ïLOWð ïOKð ïHIGHð ïïïïïïðððððð 10d ♦ Lower Limit Upper Limit After entering into the presetting mode, if intended to abort, press UNITS ESC key. 2. Setting Value Recall RECALL ⇒ to recall “lower limit” Press PRESET and then Press RECALL ⇒ to recall “upper limit” Press RECALL ⇒ to recall “buzzer” Press RECALL again ⇒ to recover the original mode. 3.
EXCELL PRECISION CO., LTD. (3). Accumulation Function 1. Weight Accumulation Place the object on the platter, after the weight display is stable, press M+ key to save the present weight value into memory. Meanwhile, the screen displays “total count accumulation” and then “total weight accumulation”, and the accumulation (M+) indication “6” will be flashing. After 3 seconds, the screen will display the weight on platter, and the accumulation (M+) indication “6” lights up.
EXCELL PRECISION CO., LTD. (6). Low Voltage Auto Power off Function Œ When the voltage of batteries is lower than 5.6v±0.1 v, it turns off backlight and the screen displays the battery symbol to intimate it needs to be recharged. • When the voltage of batteries is lower than 5.4v±0.1 v, it would auto power off; meanwhile, if turning on again, the screen would not be countdown and only displays the battery symbol. It would auto power off after 5 seconds, and it needs to recharge immediately.
EXCELL PRECISION CO., LTD. 2. Weight of Known Container ( Œ Press ) key, and the screen displays ï PRETARE BL/↑ , PRETARE G/N/↓ , TARE/← , ZERO/→ , ð ENTER , . ESC . Use keys to input the presetting value. The functions are described as below: Input the weight of container. After finished, the screen displays the negative value of the container, and the net weight (Net) and pre-tare (PT) indications light up.