Industrial Batteries – Network Power Sonnenschein A500 A powerful, universal safety package.
If reliability in power supply has priority. Specifications n The success of A500 batteries comes from the internationally superior dryfit technology n Excellent energy storage capacity combined with high reliability n Maintenance-free (no topping up) during the whole service life due to the Sonnenschein dryfit technology n Nominal capacity 1.
More power for Network Power. Applications Sonnenschein A500 batteries make an absolutely reliable means of energy source in many applications including telecommunications, security, UPS, emergency lighting, medical, railways and other power supplies for safety systems. Design life in years: 7 Nominal capacity 1.
Technical characteristics and data Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S* A508/3.5 S A512/1.2 S* A512/2 S* A512/3.5 S* A512/6.
Dimensions A502/10 S A504/3.5 S A506/6.5 S A506/1.2 S A506/10 S A506/3.5 S A508/3.5 S A506/4.2 S A512/1.
Dimensions A512/2 S A512/16 G5 Not to scale! * Dimensions are also valid for other terminals 6 A512/3.5 S A512/25 G5 A512/6.
Dimensions A512/40 A (A512/40 G6)* A512/65 A (A512/65 G6)* A512/55 A A512/85 A A512/60 A (A512/60 G6)* A512/115 A Not to scale! * Dimensions are also valid for other terminals 7
Dimensions A512/120 A A512/200 A Not to scale! * Dimensions are also valid for other terminals 8 A512/140 A
Constant current discharge 1.85 Vpc – Discharge in A at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Constant current discharge 1.75 Vpc – Discharge in A at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Constant current discharge 1.65 Vpc – Discharge in A at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Constant power discharge 1.85 Vpc – Discharge in W/block at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Constant power discharge 1.75 Vpc – Discharge in W/block at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Constant power discharge 1.65 Vpc – Discharge in W/block at 20 °C Exide type designation A502/10 S A504/3.5 S A506/1.2 S A506/3.5 S A506/4.2 S A506/6.5 S A506/10 S A508/3.5 S A512/1.2 S A512/2 S A512/3.5 S A512/6.
Notes 15
Exide Technologies, with operations in 80 countries, is one of the world’s largest manufacturers and recyclers of lead-acid batteries. Exide provides a comprehensive and customized range of stored electrical energy solutions. telecommunications systems, railway applications, mining, photovoltaic (solar energy), uninterruptible power supply (UPS), electrical power generation and distribution, fork lifts and electric vehicles.