User's Guide

Table Of Contents
The Check Synchronization button is used to check all the appliances in your system to see if the Live
RF Settings match. (The Synchronize Accounts topic has a good example of how the synchronization
feature works.)
Note
You must have a Central Management license in order to use the Check Synchronization
feature.
Click the Apply button to save your additions (changes). Click the Reset button to discard any additions
(changes).
Capabilities with a Central Engagement License
With a Central Management license, you can create configuration profiles that can be applied to all your
managed appliances. Once a profile has been created, you can synchronize the appliances so that they
are the same using the Check Synchronization button. You can also copy settings from one appliance
to all the other appliances using the Copy settings to all appliances button.
An example of using Check Synchronization is to synchronize user accounts. This checks all the
accounts on all your managed appliances and lists the dierences. You then have the option of
synchronizing selected appliances or synchronizing all appliances.
To copy settings to all appliances, when you access a feature that has the button and you want to copy
the settings, just click the Copy settings to all appliances button.
Visualizations
Visualizations configure how Live RF heat maps are visually displayed. Each visualization contains items
that are identified by a color.You can view the visualizations (shown below) by selecting one from the
Visualization drop-down menu. While viewing a visualization, you can change the default color of an
item by clicking on the color and then selecting a new color from the color chart. You may also change
the threshold (if active) by typing in a new value.
Visualization Default Colors
Signal Quality (Threshold
inactive)
Coverage Hole (Threshold
inactive)
Co-Channel Interference (default
Threshold = -120)
Network Assurance Legacy Content
1078 Extreme AirDefense User Guide for version 10.5.