Figure 75: Frame Capture Configuration
Provide the following Frame Capture configuration information:
Field Description
Frame Capture Select the scope of the frame capture. Frame capture can be limited
to either Sensor or to Device.
Frame Count Limit Limits the total number of frames to capture for each device
category. Use the spinner control to set the value.
Time Limit Specifies a time duration for the Frame Capture to run. Time can be
set in number of minutes or hours. Use the appropriate controls to
configure this value.
File Name Prefix Specifies the prefix for the frame capture file. This prefix along with
a number sequence is used to name your frame capture files.
Capture Management Frames Select to include Management Frames in your frame capture. Use
either the slider control or the Truncate After spinner control to set
the maximum number of Management Frames that will be captured
for this instance of frame capture. Capture Management Frames is
selected by default.
Capture Control Frames Select to include Control Frames in your frame capture. Use either
the slider control or the Truncate After spinner control to set the
maximum number of Control Frames that will be captured for this
instance of frame capture. Capture Control Frames is not selected
by default.
Capture Data Frames Select to include Data Frames in your frame capture. Use either the
slider control or the Truncate After spinner control to set the
maximum number of Data Frames that will be captured for this
instance of frame capture. Capture Data Frames is selected by
default.
Hover on theFrame Capture box to view a synopsis of its configuration.
Add a Device Action Manager Rule Set
Configuration
230 Extreme AirDefense User Guide for version 10.5.