Field Description
Threshold (dBm) This is the master level control for ASA scanning. Any signal levels
below the threshold during scanning will be dropped. Only levels
greater than the threshold will be admitted for further processing.
Duty Cycle (dBm) Duty cycle is a measure of the percentage (%) of utilization for each
frequency. 100% duty cycle for a frequency indicates that the
frequency is busy all the time. On the other hand, 0% duty cycle
indicates the frequency is not used at all. The Duty Cycle value
controls the threshold level for duty cycle measurement. Only signal
levels greater than the Duty Cycle threshold are counted in the duty
cycle measurement.
Settings Tab
The Settings tab of the Sensor Manager screen lets you create and manage Sensor Profiles. Sensor
profiles are a set of sensor configurations that can be applied to any sensor or a group of sensors
managed by your AirDefense server.
Sensor profiles can be created, modified, and deleted using this screen.
Important
These polices are applicable to stand alone, dedicated sensors such as M520, M510, AP300,
M400 and those sensors that support Extreme Networks WiNG 5.3 version and higher
firmware.
Select the Settings tab to load the Settings screen.
Settings Tab
Configuration
248 Extreme AirDefense User Guide for version 10.5.