User's Guide

Table Of Contents
Field Description
Max Connections Specify the maximum number of simultaneous application server
connections that can occur with this Extreme AirDefense instance.
A maximum of two thousand (2000) simultaneous application
server connections can be set.
User Session Limit Configures the number of simultaneous sessions that the same user
can have with the Extreme AirDefense appliance. By default, this
option is not enabled. It is suggested to enable this option and set
the simultaneous session value to one (1) to increase security when
permitting access to the physical Extreme AirDefense device.
An upper limit of one hundred (100) simultaneous connections can
be set for a single user.
Air Termination System Air Termination enables you to terminate the connection between
your wireless LAN and any associated Wireless Client, authorized or
unauthorized.
Select the Air-Termination system option to enable this feature.
The Policy based Air-Termination system option is only available
for use when the Air-Termination system option is selected.
Note: This setting will not be visible if you are not a user with
administrative permissions.
Policy-based Air Termination
System Enabled
Policy-based Air Termination is an automated version of Air-
Termination. This feature enables you to create and apply rules to
automatically terminate the connection between your monitored
Wireless LANs and any associated device or wireless client, either
authorized or unauthorized, based on alarms that are generated by
the Extreme AirDefense system.
Select this option to enable Policy-based Air Termination. This is
enabled by default when you enable Air-Termination system.
Note: This setting will not be visible if you are not a user with
administrative permissions.
Port Suppression System Port Suppression enables you to turn o the port on the network
switch through which a device is communicating. You can suppress
the communications port for any network device, eectively
shutting down the communication port for the device.
This is useful for devices that are connected to your network
through the physical network.
Select this option to enable Port Suppression system.
Note: You must have added SNMP Managed Switches and have full
read and write privileges to enable Port Suppression system
Auto-Logout Use this option to enable/disable the automatic logout of any
logged in user after a specified amount of time.
Select the Auto-Logout option to enable it and then use the
spinner control to set the logout time in minutes.
Note: You must log o Extreme AirDefense and then log back in
before the Auto-Logout change takes eect.
Appliance Settings Configuration
276 Extreme AirDefense User Guide for version 10.5.