User's Guide

Table Of Contents
There are two options to configure: Scope Increase Factor and Device Limit.
The Scope Increase Factor option specifies the number of network levels to expand the scope. A value
of 1 means only use the floor level. A value of 2 means use the floor and the floor's parent, and so forth.
The Device Limit option specifies a device limit. For instance, if you specify a device limit of 10 and more
than 10 devices are connected to the port, the action will not be performed.
Termination
The Termination action is used to terminate devices that generate a certain alarm defined in the filter.
To select the Termination action, select WIPS Mitigation > Termination from the Search Actions.
Alarm Action Manager
Configuration Tab
598 Extreme AirDefense User Guide for version 10.5.