h. Click Apply.
8. Ensure that the device firmware is current. (Configuration > Infrastructure Management > Device
Firmware). If firmware is not current, update it.
9. Create a Radio Settings configuration for the AP-7131 and apply it to the floor the device is placed.
You must include some data rates.
Note
ADSP automatically sets up a default Radio Settings profile. Only follow these steps, if you
want to use your own settings.
a. Go to Configuration > Infrastructure Management > Radio Settings.
b. Select the floor.
c. Select Override settings.
d. Select the proper settings.
e. Click Apply.
10. Configure RF-Domain and apply to by selecting the scope where the floor the AP-7131 is placed as
follows:
a. Go to Configuration > Infrastructure Management > RF-Domain.
b. Select the floor.
c. Select Override settings.
d. Enter RF-Domain information.
e. Click Apply.
11. Create WLAN profile and apply it by associating the profile with the location that contains the
managed device.
a. Go to Configuration > Infrastructure Management > WLAN Profiles.
b. Click New Profile.
c. Enter information for the WLAN Profile in the General and Security tabs.
d. Click OK.
e. Ensure that the appliance is selected in the network tree and select Enable configuration.
f. Select the floor.
g. Select Override settings.
h. Select the WLAN Profile.
i. Click Apply.
The profile is now complete but ADSP cannot communicate with the AP-7131.
12. If you have not already done so during the Platform configuration, import the AP-7131 into your
network using SNMP discovery using a single IP address. This can be done with Configuration >
Appliance Platform > Import/Discover Devices.
Note
Select SNMP discovery with a target folder of a floor created in the Appliance Platform
configuration. You can use the Device Import Rules or manually select the floor.
13. Set automatic status polling and automatic data collection for 3 minutes, and turn on automatic
configuration correction (Configuration > Appliance Platform > Polling).
14. If necessary, configure the Communication Settings so that ADSP can communicate with the
AP-7131. HTTP is only used for Airwave and WLSE devices so this is not needed for the AP-7131. In
Configuration
Examples Configuration Tab
728 Extreme AirDefense User Guide for version 10.5.