If you are running the Readiness Test from a device, it is run only on that device. If you are running the
Readiness Test from a network folder (level), the test is run on all the devices included in that folder.
There are four categories of tests: Appliance Configuration, Management Modes, Device
Communication Verification, and Relay Server Communication Verification. Each category can be
expanded to review individual tests for that category by clicking the category. Each of the tested items
is marked as a success - , a problem - , or a caution area - . If all the tests under a category are
successful, the category is marked as a success. If one test under a category has a problem, the
category is marked as a problem area. You can click on any category to display the tests for that
category. If a test is marked as a problem or caution area, you can click on the test to navigate to the
problem area and take action to correct the problem.
Appliance Configuration
There are four tests for Appliance Configuration:
License Assigned—validates that the number of licenses do not exceed the number of configured
devices.
Polling Configuration—validates that the folder or device selected inherits a configured polling
profile.
Communications settings—validates that the folder or device selected inherits a configured
communication settings profile.
Relay server settings—validates that the folder or device selected inherits a configured relay server
profile.
Management Modes
Device Functions Requiring More Explanation
Configuration Tab
788 Extreme AirDefense User Guide for version 10.5.