Quick Reference Guide

X590 Series Switch Quick
Reference
Follow these steps to get your switch up and running.
For complete installation instructions see the ExtremeSwitching and
Summit Switches: Hardware Installation Guide at
www.extremenetworks.com/documentation
Tools You’ll Need
Appropriate grounded power receptacles
located within 1.8 m (6 ft.)
A readily accessible device for disconnecting
power, such as a breaker or master switch
Network cabling within reach
At least of 7.6 cm (3.0 in.) on all sides, for
proper ventilation
Temperature between 0°C (32°F) and 45°C
(113°F) with fluctuations of less than 10°C
(18°F) per hour
If the switch appears to be damaged, contact Extreme Networks. See
“Getting Help” for more information.
Extreme Networks does not include power input cords with this product.
To purchase the correct power cord for your country, refer to
www.extremenetworks.com/product/powercords/. This page lists
details for purchasing a power cord from Extreme Networks or from
your local supplier.
1 #2 Phillips screwdriver
(magnetic screwdriver recommended)
3 Rack-mounting screws
2 Flat-head screwdriver 4 ESD-protective wrist strap
1
Prepare the Site
The installation site must meet the following requirements:
2
Unpack the Box
Remove the packing material. Break the tape seal on the
non-conductive bag and remove the switch.
1 Switch (48-port model shown) 3 Bracket screws
2 Mounting brackets
There are four ways to mount the X590 Series switch in a rack:
Either the I/O ports or the power-supply side can face front.
The switch can be mounted flush with the rack posts or mid-
mounted.
Note: The following diagrams show a mid-mounted configuration. Other
options are shown in the Hardware Installation Guide.
1 Attach the mounting brackets to the sides of the switch using six
screws (included) for each bracket.
2 Align the holes in the brackets with the rack post holes.
3 Secure the switch to each post with fasteners appropriate to the rack.
1
1 Attach the ESD wrist strap to your wrist and connect the metal end
to an appropriate ground point on the rack.
2 Remove the transceiver from its packaging.
3 If applicable, remove the protective dust cover from the connector.
4 Hold the transceiver so that the connector will seat properly.
5 Carefully align the transceiver with the port slot.
6 Push the transceiver into the port slot until it clicks into place.
3
Install the Switch
You can install any X590 Series switch in a standard 19-inch
equipment rack.
4
Install Transceivers
(Optional) Transceivers can send and receive data over
optical fiber rather than through electrical wires. This
installation procedure applies to all transceivers.
Note: Transceivers are Class 1 or Class 1M laser devices.
Connecting to the Primary Power Source
To attach your X590 Series switch to a power source, do the following:
1 Connect the AC power cord to the AC power input socket on the
power supply and an AC power outlet.
2 For DC powered supplies, verify that the DC circuit is de-energized
and then do the following:
a Identify the grounding stud on the DC power supply. The grounding
stud is next to the DC input connector, identified by the international
symbol for earth ground.
b Using the nut and washer provided, connect the ring terminal end of
the ground wire to the grounding stud on the DC power supply.
Use green and yellow stranded copper wire, sized at least 14 AWG.
c Connect the other end of the ground wire to a reliable earth ground.
d Connect the DC power input cables to the DC input connector
provided.
Use copper wires rated for at least 60°C and sized between 14 AWG
and 8 AWG.
e Energize the circuit.
3 When power is connected, verify that the switch’s PWR LED turns
green. If the PWR LED does not turn green, refer to the Hardware
Installation Guide for troubleshooting information.
Safety Notices
5
Connect Power
X590 Series switches can run on AC or DC power. Connect
the switch to a primary power source.
Note: Installing the system as described in this guide meets the
protective earth grounding requirements of the National Electrical
Code (NEC), UL/CSA/IEC/EN 60950-1 standards. However, in some
cases, it may be necessary to use an alternative grounding method.
In these cases, a 14 AWG wire can be connected between the
grounding lug on the chassis and a nearby building ground point.
6
Configure the Switch
To connect the switch to the network and configure it for
use, follow the steps in www.extrconfig.com/exos.
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Risques d’électrocution: Seul un personnel qualifié doit effectuer
les procédures d'installation.
Warning: Extreme Networks power supplies do not have switches for turning
the unit on and off. Before servicing, disconnect all power cords to remove
power from the device. Make sure that these connections are easily accessible.
Avertissement: Extreme Networks alimentations ne sont pas des interrupteurs
pour allumer l'appareil et en dehors. Avant l'entretien, débranchez tous les
cordons d'alimentation pour couper l'alimentation de l'appareil. Assurez-vous
que ces connexions sont facilement accessibles.
Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each
power supply connection.
Avertissement: Un disjoncteur cotée dédiée évalué à 15A doit être utilisée pour
chaque connexion d'alimentation.
Caution: Before mounting the device, ensure that the rack can support it
without compromising stability. Otherwise, personal injury and/or equipment
damage may result.
Caution: Follow appropriate ESD procedures when unpacking and handling
the switch. These include unpacking the switch in an ESD-safe environment
and wearing appropriate ESD protective gear, such as ESD-safe footwear and
ESD wrist straps where appropriate.
Caution: Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Warning: Do not use optical instruments to view the laser output. The use of
optical instruments to view laser output increases eye hazard. Use only
UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.
Avertissement: Ne pas utiliser d'instruments optiques pour voir la sortie du
laser. L'utilisation de instruments optiques pour afficher la sortie laser
augmente les risques oculaires. Utilisez uniquement UL/CSA,
IEC/EN60825-1 /-2 reconnu modules enfichables.
Hardware Components
Figure 1 X590 Series Switch: Front Panel (24t Model Shown)
Figure 2 X590 Series Switch: Rear Panel
For component details, see the Hardware Installation Guide.
Operating Conditions
Operating Temperature:
0°C (32°F) to 45°C (113°F)
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
5% to 95% (non-condensing)
Interfaces
Each X590 Series switch has a management port, a console port, and a
USB port. The following table lists the specific interfaces for each switch.
Note: The X590 ExtremeXOS Core License (Part no. 16795) is optional.
Power Specifications
Power Supply and Fan Options
1 Console/management port 4 10Gb/40Gb QSFP+ port
2 USB port 5
10Gb/25Gb/40Gb/50Gb/100Gb
capable
QSFP28 ports
3 100Mb/1Gb/10GBASE-T ports (24t) or
1Gb/10Gb SFP+ ports (24x)
1
Grounding lug 3 Modular power supply (AC input
shown)
2
Fan modules
X590-24t-1q-2c
(Part no. 16791)
X590 base unit with 24 100Mb/1Gb/10GBASE-T ports,
1 10Gb/40Gb QSFP+ port, 2 10Gb/25Gb/40Gb/50Gb/
100Gb capable QSFP28 ports, 2 unpopulated power
supply slots, 4 unpopulated fan module slots,
ExtremeXOS Advanced Edge License
X590-24x-1q-2c
(Part no.16790)
X590 base unit with 24 1Gb/10Gb SFP+ ports, 1 10Gb/
40Gb QSFP+ port, 2 10Gb/25Gb/40Gb/50Gb/100Gb
capable QSFP28 ports, 2 unpopulated power supply
slots, 4 unpopulated fan module slots, ExtremeXOS
Advanced Edge License
X590-24t-1q-2c
(Part no. 16791)
AC Input: 100-127VAC, 2.5A max. 50-60Hz for each PSU
AC Input: 200-240VAC, 1.25A max. 50-60Hz for each PSU
DC Input: -48 to -60VDC, 5.0A max. for each PSU
X590-24x-1q-2c
(Part no.16790)
AC Input: 100-127VAC, 2.5A max. 50-60Hz for each PSU
AC Input: 200-240VAC, 1.25A max. 50-60Hz for each PSU
DC Input: -48 to -60VDC, 5.0A max. for each PSU
X590-24t-1q-2c
X590-24x-1q-2c
Part no. 10960 770W AC power supply, Front-to-Back airflow
Part no. 10961 770W AC power supply, Back-to-Front airflow
Part no. 10962 1100W DC power supply, Front-to-Back airflow
Part no. 10963 1100W DC power supply, Back-to-Front airflow
Part no. 17115 X870 Fan Module, Front-to-Back airflow
Part no. 17116 X870 Fan Module, Back-to-Front airflow

Summary of content (2 pages)