User’s Manual CIA111, CIA114, and CIA114F5 Wall Box and Floor Box Mountable Interfaces www.extron.com Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng Rd. #04-01 PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664 © 2008 Extron Electronics.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没 有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与 厂家推荐的相同
Chapter One • Introduction ..................................................... 1-1 About this Manual ..................................................................... 1-2 About the CIA111, CIA114, and CIA114F5 .......................... 1-2 Features ......................................................................................... 1-2 Chapter Two • Installation and Operation . .................. 2-1 Installation Overview . ..............................................................
Table of Contents, cont'd CIA111 and CIA114 Computer Video Interface 1 Chapter One Introduction About this Manual About the CIA111, CIA114, and CIA114F5 Features 68-809-01 Rev. C 02 08 All trademarks mentioned in this manual are the properties of their respective owners.
Introduction About this Manual This manual contains information about installing and operating the Extron CIA111, CIA114, and CIA114F5 interfaces. About the CIA111, CIA114, and CIA114F5 The Extron CIA111, CIA114, and CIA114F5 are wall box or floor box mountable computer video interfaces. The CIA111 mounts to a wall or podium using a two-gang junction box and has mounting spaces for up to four single-space Mini Architectural Adapter Plates (MAAPs).
Installation Installation Overview C Front Panel Features and Cabling Installation and service must be performed by authorized personnel only. UL Listed electrical boxes are recommended. See "UL Requirements", later in this chapter. To install and set up a CIA111, CIA114, or CIA114F5 interface, follow these steps: 1 2 3 4 5 6 Turn all of the equipment off.
Installation, cont’d e 4 Audio Input connector — Plug a computer audio source into this 3.5 mm stereo jack. Wire the connector as shown in figure 2-2. Tip (+) Sleeve 2 3 Ring (-) Tip (+) Sleeve ( ) 3.5 mm Audio Plug Figure 2-2 — Tip, ring, and sleeve f 5 Auto Power LED — This LED lights to indicate that a VGA input cable has been connected to the front panel Computer Input connector and the interface has automatically turned itself on.
Installation, cont’d e Mode Select DIP switches — Set these switches to select settings for horizontal position control, sync format, monitor emulation, and Auto Power. 1 — Image Shift control On — The Image Shift button is enabled and shifts the location of the image when pressed (default). Off — The Image Shift button is disabled and does not shift the location of the image when pressed.
Installation, cont’d When the image is displayed correctly C Once the system has been cabled and tested, the interface can be installed in the wall or furniture. To mount the interface and install optional MAAP devices (CIA111 only), see the next section, "Mounting the Interfaces". UL Requirements The following Underwriters Laboratories (UL) requirements listed pertain to the installation of the CIA111 and CIA114 interfaces into a wall or furniture. LAN/WAN Network/ Internet Sound System NO 1.
Installation, cont’d 6. Insert the wall box into the opening, and attach it to the wall stud or furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface (figure 2-6). Wall Stud 2-gang Wall Box Screws or Nails Extron CIA111 Cable Clamp NO IM AG E SH MO CO Installation Cable Figure 2-6 — Attaching the wall box to a wall stud If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 1/2 inch (1.
Installation, cont’d Mounting the interface to the wall box 1. Remove power from the interface by disconnecting the power supply. 2. 3. Place the interface through the opening in the wall or furniture and into the wall box. Take care not to damage the cables, which fit behind the interface, at the back of the wall box. Mount the interface’s faceplate to the wall box with the provided machine screws (figure 2-8).
Installation, cont’d Preparing the site and cables 1. Choose a location that allows cable runs without interference. Allow enough depth for both the floor box and the cables. You need to run the conduit (if required by local code) and cables under the floor before installing the interface. 2. Install the floor box in accordance with the documentation that accompanied the box. 3. Feed cables through the floor box punch-out holes, and secure them with cable clamps to provide strain relief. 4.
Reference Information Specifications Audio Video Gain.................................................. Unity Bandwidth....................................... 250 MHz (-3 dB) Video input and loop-through Number/signal type...................... 1 VGA–UXGA, Mac, Sun RGBHV, RGBS, RGsB 1 buffered local monitor loop-through identical to the input N Sync is not stripped from green. RGsB input signals are output as RGsB. Connectors...................................... 2 female 15-pin HD Nominal level.....
Reference Information, cont’d Rack mount CIA111, CIA114................... No, but wall or furniture mountable CIA111AM........................... No, but Ackerman® GB3 floor box mountable CIA114F5............................. No, but Steel City® 665 floor box mountable CIA114AM........................... No, but Ackerman® GB2 floor box mountable Enclosure type................................ Metal Enclosure dimensions CIA111 faceplate............................. 4.5" H x 5.0" W x 0.1" D (11.4 cm H x 12.
Reference Information, cont’d Accessories These items can be ordered separately: Accessories Part numbers Modular A/V panel for Steel City 665 floor box (for CIA114F5 only) 60-585-11 5.0" (12.7 cm) Assorted MAAPs (CIA111 only) Cables and Adapters Cables and adapters Part numbers VGAM 6' MHRA cable with audio 26-490-02 Mac adapter VGAM kit with audio 70-156-01 13W3 adapter VGAM kit with audio 70-157-03 4.1" (10.5 cm) 4.5" (11.4 cm) Top Panel 3.0" (7.
Reference Information, cont’d 2.75" (7.0 cm) 2.1" (5.3 cm) Top Panel 4.5" (11.4 cm) 3.0" (7.6 cm) Location of CIA114 SURFACE CUT-OUT AREA FOR FURNITURE MOUNT To install CIA114 directly into furniture, cut along this line. TEMPLATE IS NOT FULL SIZE.