User’s Manual HSA 800 & 802 Up Hideaway Surface Access Products www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the HSA Hideaway Enclosures ......................... 1-2 Features ...................................................................................... 1-4 Chapter 2 • Installation ............................................................. 2-1 Installation Overview .......................................................... 2-2 Preparing the Routing Template ..................................
Table of Contents, cont’d Surface Access Products 1 Chapter One Introduction About the HSA Hideaway Enclosures Features ii Surface Access Products • Table of Contents
Introduction About the HSA Hideaway Enclosures The Extron Hideaway HSA 800 and HSA 802 are furnituremounted, architectural solutions for inconspicuous computer video interface connector access and control. The HSA 800 provides space for two double-space (doubleheight) or four single-space Extron Architectural Adapter Plates (AAPs), a standard grounded US, IEC, UK, Europe, or Australian (depending on the model) AC receptacle, and two RJ-45 (Category 6) (CAT 6) connectors (figure 1-1).
Introduction The HSA 800 and HSA 802 are available in a variety of surface finishes, including black anodized metal, brushed aluminum, brushed brass, polished aluminum, and polished brass.
Installation These strips raise the routing template above the mounting surface to provide room for the router’s collar, protect the mounting surface, and extend the reach of the routing template so that it can be clamped to the edge of the surface. Installation Overview Install and set up the HSA surface access enclosures as follows: 1 2 If you have an unprepared mounting template, prepare the template. See Preparing the Routing Template in this chapter.
Installation, cont’d template, you will cut an improperly-sized hole. If you use a larger template than required, the cut will result in gaps in the table surface on either side of the enclosure. The surfaces of the HSA enclosure have screws and other protruding hardware that could damage fine furniture. Do not rest the enclosure on unprotected furniture. Wear safety glasses when operating the router. Failure to comply can result in eye injury. 4.
Installation, cont’d Cabling and Installing the AAPs INP SE UT LE CT CO MP AU UT ER Extron’s various single- and double-space AAP devices, including the various RGB 580xi AAPs, can be mounted to the HSA 800 or HSA 802. See appendix A, Specifications, Part Numbers, and Accessories, for RGB 580xi AAP part numbers. DIO HSA 802 The screws needed for installing an AAP are built into its front panel, so no additional screws are needed. Ensure that AC power is disconnected before servicing the HSA unit.
Installation, cont’d needed, four spare screws are stored in the underside of the enclosure. #4-40 Nut w/ Captive Washer Front Panel HS A8 An RJ-11 plug can be connected to the RJ-45 jack. When cabling the front and bottom panels, the bottom RJ-45 connectors match up with the front panel RJ-45 connectors shown in figure 2- 7 (US/domestic) or figure 2-8 (IEC and all international versions).
Installation, cont’d If necessary, on the front panel, have a qualified service person replace the connector icon by prying the old icon off of the connector plug-in with a tweeker (figure 2-9) and snapping a new icon in place.
Installation, cont’d Surface Access Products 3 Chapter Three Maintenance and Modifications Replacing an AAP Replacing the Bezels Removing and Replacing the Enclosure Adding a Second Connector Panel Replacing the Gas Lift Adjusting the Top Surface 2-12 Surface Access Products • Installation
Maintenance and Modifications The HSA 800 and HSA 802 surface mount enclosures can be modified in the future to replace an AAP or to add a second connector panel (with all of the associated cables) to an HSA 800. The most probable corrective maintenance procedures required are leveling the top surface and replacement of the gas lift. Most of the maintenance procedures require removing the surface mount enclosure from the table.
Maintenance and Modifications, cont’d 2. 5. With a tweeker, push down on and gently twist on the front of each RJ-45 connector detent to disconnect the connector from the rear of the front panel plug-in. 3. Pinch the top and bottom bezel detents together and push the bezel through the front panel. 4. Snap a replacement bezel in place. If necessary, replace the connector icon by prying the old icon off of the connector plug-in with a tweeker (figure 2-9) and snapping a new icon in place. enclosure.
Maintenance and Modifications, cont’d HSA 802 125 INP SE UT LE CT CO MP AU UT ER 50/60 Hz A 0.5 DIO Remove 16 screws Shroud Mounting Surface AAP Cables Figure 3-4 — Disconnecting the interior AC cable Clamshell 18. Connect the IEC power cord and RJ-45 cables to the connectors on the underside of the surface mount enclosure. 19. To prevent wear and tear caused by cable movement, secure the AAP cables underneath the table. See Routing the AAP Cables in chapter 2, Installation.
Maintenance and Modifications, cont’d 1. Remove the surface mount enclosure. See Removing and Replacing the Enclosure, steps 1 through 9. Place the enclosure on a horizontal surface. 2. Insert the new RJ-45 connector bezel plug-ins through the holes in the bottom of the surface mount enclosure. 3. Snap the interior RJ-45 cable connectors onto the rear of the bottom RJ-45 connector bezel plug-ins. 4. Connect the internal cables to the inside of the bottom RJ-45 connectors. 5.
Maintenance and Modifications, cont’d frame. Carefully draw the gas lift out through the top of the enclosure frame. Height Adjustment Screw Insert the shaft end of the replacement gas lift through the hole in the lifting platform. Thread the shaft of the gas lift into the frame clevis nut and tighten it several turns. 6. CAUTION Ensure that the top panel bracket does not contact the top flange.
Maintenance and Modifications, cont’d Locking Screws Adjustment Screws Locking Screws (1 concealed) Surface Access Products A Appendix A Figure 3-6 — Location of level adjustment and locking screws 4. Carefully turn the three adjustment screws on the underside of the top panel to level the top panel with the flange. 5. Tighten the six screws that you loosened in step 3. 6. Reinstall the surface mount enclosure. See Removing and Replacing the Enclosure, steps 11 through 19.
Reference Information Specifications Part Numbers HSA 800/802 US General Rack mount .................... No, but furniture mountable Enclosure type ............... Metal Enclosure approximate dimensions Top pla te (outer rim) ................................................. 8.5” W x 8.8” D (21.5 cm W x 22.2 cm D) Top plate (lifting plate) ............................................... 6.2” W x 6.5” D (15.8 cm W x 16.5 cm D) Clamshell (figure A-1) ................................................ A = 7.
Reference Information, cont’d HSA 800/802 EU Included Parts HSA 802 EU Enclosure (polished aluminum) 60-418-24 Part HSA 802 EU Enclosure (brushed brass) 60-418-25 HSA 800/802 HSA Hideaway Products manual 68-617-01 HSA 802 EU Enclosure (polished brass) 60-418-26 Snap-in icon inserts 40-348-01 RJ-45 connector bezel plug-in inserts (assorted colors and blank) 70-201-01 HSA 800/802 UK Part number Part number 1/4 - 20, 1”, 1-1/2”, 2”, 2-1/2” full thread bolts HSA 800 UK Enclosure (black anodiz
Reference Information, cont’d HSA 800/802 A 8.47” (21.5 cm) B 8.75” (22.2 cm) C 7.97” (20.2 cm) D 8.25” (21.0 cm) E 6.2” (15.7 cm) F 6.4” (16.3 cm) G 0.5” (1.3 cm) H 0.25” (0.6 cm) Top Plate Dimensions The cut-out template (figure A-2) is not to scale and is for reference only. If you choose not to use Extron’s routing template (chapter 2, Installation), the dimensions shown on the table on page A-7 will help you properly prepare the mounting surface.
Reference Information, cont’d Surface Access Products Page intentionally left blank B Appendix B Packaging for Shipment A-8 Surface Access Products • Reference Information
Packaging for Shipment The HSA 800’s and HSA 802’s ultra-fine machined surfaces and moving parts make them vulnerable to damage caused by mishandling during shipment if they are improperly packaged. If, for any reason, you need to return an HSA to Extron, first contact Extron to obtain a return kit. The return kit, which reduces the chances of damage during shipment, includes a sturdy shipping carton and foam cut to fit the HSA (figure B-1).
Packaging for Shipment, Cont’d 6. Release (extend) the top panel. 7. Insert the HSA 800/802 and the clamshell into one of the foam shells (figure B-4). Either open end of the clamshell and the open top panel will fit into the recesses in the foam. Figure B-5 — HSA suspended in the foam Figure B-4 — Installing the foam shell 8. Insert the opposite end of the HSA 800/802 and the clamshell into the remaining foam shell (figure B-5).
Packaging for Shipment, Cont’d Page intentionally left blank B-6 Surface Access Products • Packaging for Shipment