User's Manual

1
Mounting and Cabling
Step 1 — Mounting
Turn off or disconnect all equipment power sources and rack mount the
DVS 605 unit using the pre-installed brackets (see gure 1 at right).
Optional furniture mounting brackets (MBU 149) can be used to mount
the unit under a table or desk top (see gure 2 at right).
Step 2 — Connect inputs
Connect inputs from video sources to the applicable connectors
marked “Inputs”. See a and b for video connectors and c for audio connectivity.
Step 3 — Connect outputs
Connect video and audio output devices to the applicable connectors marked
“Outputs” (see d through j above).
Step 4 — Connect control devices
LAN port
l
— Connect a LAN or WAN via this RJ-45 connector
for remote control of the DVS 605 using an Internet browser via
a connected PC.
NOTES: Default IP address is 192.168.254.254
DHCP is disabled.
One connection LED lights green when connected to the LAN and one ickers
amber as the devices communicate.
NOTE: Do not use standard telephone cables for LAN connection, as they do
not support Ethernet or Fast Ethernet.
Do not stretch or bend cables as transmission errors could occur.
RS-232/IR port — For serial RS-232 control, connect a host computer or
control system to the 5-pole captive screw connector
m
.
RS-232 protocol (default values):
9600 baud, 1 stop bit, no parity, 8 data bits, no ow control.
By default the IR port is disabled.
Contact closure port — For remote input selection of any of the ve inputs, connect a suitable contact closure control device to the
5-pole captive screw connector
n
. The contact closure port and the RS-232 port share a common ground.
Step 5 — Connect power
AC power connector — Plug in a standard IEC power cord from a 100 - 240 VAC, 50 - 60 Hz power source into this receptacle
o
.
DVS 605 • Setup Guide
The Extron DVS 605 Digital Video Scalers are scaling products that allow most common signal formats to be processed, scaled, and
output in any desired format. This setup guide allows an experienced user to easily and quickly set up and congure a
DVS 605 using step by step instructions. It covers how to perform basic operations using the front panel controls and selected
Simple Instruction Set (SIS
) commands.
NOTE: For full installation, configuration, menus, connector wiring, and operation details, see the DVS 605 User Guide, available at
www.extron.com
Rack Mount
Bracket
L
1
R L
2
R L
3
R L
4
R L
5
R L
FIXED
R
L
VARIABLE
R
100-240 VAC ~ .7A MAX
50/60Hz
RGB/R-Y, Y, B-Y
1
5
2
3
4
UNIVERSAL
AUX
HDMI
HDMI
GENLOCK
3G/HD - SDI
RS-232 IR
Tx Rx SGG
CONTACT
12345
S/PDIF
FIXED
LAN
RESET
INPUT OUTPUTS REMOTE
AUDIO INPUTS AUDIO OUTPUTS
DVS 605 AD
14
13
7
6
2
3
8 9
10
15
4
5
1
11
12
Installation
Rear Panel Features
The DVS 605 AD is shown here. All other DVS 605 models have some but not all of the features shown below.
Figure 1. Rack Mount
Figure 2. Furniture Mount
#8 Screw
(4) Places
Each Side
MBU 149
Mounting Bracket
Mounting Screws
(2) Places
Each Side

Summary of content (4 pages)