User’s Manual MTP SW6 6-Input, 1-Output, Mini Twisted Pair Switcher Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron EMEA Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没 有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与 厂家推荐的相同
Table of Contents Chapter One • Introduction ..................................................... 1-1 About the MTP SW6 Switcher . .............................................. 1-2 RS-232 function ....................................................................... 1-3 Twisted Pair (TP) Cable Advantages . ................................... 1-4 Transmission distance ............................................................. 1-4 Chapter Two • Installation and Operation . ..................
Table of Contents, cont’d Appendix A • Reference Information ..............................A-1 Specifications ...............................................................................A-2 Part Numbers ...............................................................................A-5 Included parts .........................................................................A-5 Accessories ..............................................................................A-5 Cables ..............................
Introduction About the MTP SW6 Switcher The Extron MTP SW6 is a 6-input, 1-output mini twisted pair (MTP) switcher that is compatible with the entire line of Extron MTP transmitters and receivers. The Extron MTP transmitters and receivers are a system for long-distance distribution of video and either audio or RS-232 communications.
Introduction, cont’d 1-4 MTP SW6 • Introduction 400' (120 m) 400' (120 m) 400' (120 m) 300' (90 m) <250' (75 m) HDTV 1080p >300' (90 m) 500' (150 m) 400' (120 m) 400' (120 m) 500' (150 m) 500' (150 m) 400' (120 m) 300' (90 m) 400' (120 m) <250' (75 m) HDTV 1080i >300' (90 m) <250' (75 m) HDTV 720p >300' (90 m) 400' (120 m) 400' (120 m) 400' (120 m) 300' (90 m) <250' (75 m) >300' (90 m) 450' (135 m) 450' (135 m) 450' (135 m) 300' (90 m) >300' (90 m) 400' (120 m) 400' (120 m) 400' (120 m) 4
Recommended transmission distances at 60 Hz Video format MTP SW6 Pre-Peak High quality Variable quality MTP SW6 • Introduction 1-5 Off On Input a Output b Input a Output b Component, S-video, composite <300' (90 m) >350' (105 m) 700' (215 m) 700 (215 m) 700' (215 m) 800 (245 m) 640 x 480 <300' (90 m) >350' (105 m) 550' (170 m) 600' (185 m) 550' (170 m) 700' (215 m) 800 x 600 <300' (90 m) >350' (105 m) 500' (150 m) 500' (150 m) 600' (185 m) 600' (185 m) 1024 x 768* <300' (90
Introduction, cont’d MTP SW6 2 Chapter Two Installation and Operation Mounting the Switcher Connectors and Settings Operation Optimizing the Video 1-6 MTP SW6 • Introduction
Installation and Operation Mounting the Switcher The MTP SW6 can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or tabletop. Rack shelf mounting instructions 1. Remove feet from the bottom of the MTP SW6 if installed. 2. Tabletop use Four self-adhesive rubber feet are included with the switcher. For tabletop use, attach one foot at each corner of the bottom side of the unit and place the unit in the desired location.
Installation and Operation, cont’d 1U Universal Rack Shelf Furniture mounting For furniture mounting, do not attach the rubber feet. Furniture mount the switcher using the optional MBU 125 under desk mounting kit (part #70-077-01) as follows: 1. Remove feet from the bottom of the MTP SW6 if installed. 2. Attach the furniture mounting brackets to the switcher with the four machine screws supplied with the mounting kit (figure 2-3). Figure 2-2 — Mounting the MTP SW6 on a 1U, 9.
Installation and Operation, cont’d Connectors and Settings N 5 MTP SW6 RS-232 INSERT OUTPUT INPUT POWER 12V 0.5A MAX PRE-PEAK ON Tx Rx SPARE REMOTE MONO AUDIO OUTPUT L c R OFF 1 2 3 1 4 2 5 4 6 7 See "TP Cable Termination", on page 2-10, to properly wire the RJ-45 connectors. Figure 2-4 — Switcher’s rear panel features a DC power connector — Plug the external 12 VDC power supply into this 2-pole captive screw connector.
Installation and Operation, cont’d f Mono Audio (local audio) output — Connect an audio device, such as an audio amplifier or powered speakers to this 3.5 mm, 5-pole captive screw connector. This connector outputs the selected unamplified, mono line level audio. See figure 2-6 to properly wire the output connector. Use the supplied tie-wrap to strap the audio cable to the extended tail of the connector.
2-10 MTP SW6 • Installation and Operation Reserved Reserved Blue-/H. syncBrown Brown 8 NOTE If you are using Enhanced Skew-Free™ A/V cable, use the TIA/EIA T568A standard only. RS-232Reserved Reserved White-brown 7 White-brown Blue+/H. sync+ VideoGreen6 White-blue White-blue Orange 5 Blue Blue 4 Green+ Luma (Y)- Mono audio- Mono audio+ Luma (Y)+ Video+ Chroma (C)Reserved Red–/V.
Installation and Operation, cont’d Receiver considerations The receivers' buffered outputs do not provide pre-peaking control. The total recommended distance for an entire daisy chain is the same as for a single transmitter and receiver. The transmitter's Pre-Peak switch has the same affect on the recommended transmission distance for a daisy chain as for a single transmitter and receiver. N See the recommended transmission ranges in the table on page 1-5.
Installation and Operation, cont’d h Delay Adjust (skew adjustment) control — This control delays the selected red, green, or blue video signal by up to 62 nanoseconds. The delay is applied in incremental, 2-nanosecond, steps. Rotate the control counterclockwise to reduce the delay or clockwise to increase the delay. The control’s movement is smooth; it does not have mechanical steps or high- and low-limit stops.
Installation and Operation, cont’d Optimizing the Video Most MTP transmitters and the MTP SW6 output have a prepeaking feature. Set these features as follows for the best image quality: 1. 2. For inputs from MTP T 15HD products only — If the cable between the MTP transmitter and the MTP SW6 is > 300', turn the transmitter’s Pre-Peak switch on. For shorter cables, turn the switch off. For the output — If the cable between the MTP SW6 and the receiver is > 300', turn the switcher’s Pre-Peak switch on.
Installation and Operation, cont’d 4. Adjust the leftmost video signal as follows: N The switcher cannot shift the rightmost video image to the left. a. Use a Tweeker or other small screwdriver to press and release the Delay Select button until the LED lights for the left-shifted color — Delay Red, Green, or Blue. b. Slowly rotate the Delay Adjust control clockwise while monitoring the display. Observe that the leftmost color shifts rightward one step at a time.
Remote Control The switcher can be remotely controlled via its rear panel Remote connector (Figure 3-1).
Remote Control, cont’d Unit-initiated messages When a local event, such as a front panel operation, auto switch, or error condition, occurs, the unit responds by sending a message to the host. The unit-initiated messages are listed below: (c)Copyright 2008, Extron Electronics "MTP SW6", x.xx]] The connected unit issues the appropriate copyright message (above) when it first powers on. x.xx is the firmware version number.
Command ASCII Command MTP SW6 • Remote Control (host to unit) Response (unit to host) Additional description Input selection N The switcher supports 1-, 2-, and 3-digit numeric entries (1!, 02&, or 003%). The switcher reports all selections with 1-digit numbers. N The & select and the % select commands for video can be used interchangeably.
Command ASCII Command MTP SW6 • Remote Control (host to unit) Response (unit to host) Additional description Skew adjustment Set all skew adjustment values for an input EX!*X%*X%*X%Iseq} Set a specific skew adjustment for the TP input. values are listed in RGB order. X% E2*0*0*4Iseq} IseqX!*X%*X%*X%] Iseq02*00*00*04] Increment one input's skew adjustment value EX!*X^+Iseq} IseqX!*X%*X%*X%] Increase input X!'s X^ plane’s skew adjustment by 1 step (2 ns).
Command ASCII Command MTP SW6 • Remote Control (host to unit) Response (unit to host) Additional description Audio input gain and attenuation N The set gain (G) and set attenuation (g) commands are case sensitive. The increment, decrement, and read commands are not case sensitive. Set input audio gain to X!*X(G InX!•AudX1)] +dB value Example: 1*2G Set input 1 audio gain to +2 dB. In01•Aud+02] X!*X1!g InX!•AudX1)] X!+G 5+G InX!•AudX1)] Increase gain by 1 dB.
Command MTP SW6 • Remote Control ASCII Command Response Additional description 1# F1] 2# F2] The user selects inputs manually, from the front panel or under remote control. The switcher automatically switches to the highest numbered input with signals present. Manual switching is disabled. 1X Exe1] Enable Lock mode 1. 0X Exe0] Enable Lock mode 0.
Command MTP SW6 • Remote Control ASCII Command Response Information request I Request part number N VX!•AX!•FX1$•VmtX1#•AmtX1#•ExeX1#] V (selected video input)•A (selected audio input)• F (switch mode)•Vmt (video mute — not supported by this switcher)•Amt (audio mute)•Exe (front panel lock). See appendix A for part numbers. 68-928-01] Query controller firmware version Example: Q X1%] Q 1.
Remote Control, cont’d 3-14 The Windows-based Extron Universal Switcher Control Program, which communicates with the switcher via the Remote port, provides an easy way to configure and operate the MTP SW6 switcher. The program is compatible with Windows 2000 and Windows XP or higher versions. The factory-installed controller firmware version is 1.23 (sample value only). Installing the software The program is contained on the Extron Software Products CD-ROM, disk B. Install the software as follows: 1.
Remote Control, cont’d 4. Follow the on-screen instructions. By default, the installation of the Universal Switchers Control Program creates a C:\Program Files\Extron\UniversalSwitcher, and it places four icons into a group folder named “Extron Electronics\Universal Switcher.” The four installed icons are: • To set up for audio follow switching (the output has the same audio and video input selected), select the Audio and Video check boxes.
Remote Control, cont’d Contact Closure Remote Control The Remote connector also provides a way to select an input to the switcher using a remote contact closure device. Contact closure control uses pins on the Remote connector that are not used by the RS-232 interface. Figure 3-5 shows the contact closure pin assignments.
Reference Information Specifications Video Gain ������������������������������������������������� Unity Video input — see MTP Series transmitter specifications Number/signal type ��������������������� 6 sets of proprietary analog signals Connectors ������������������������������������� 6 female RJ-45 Video output — See MTP Series receiver specifications Number/signal type ��������������������� 1 set of proprietary analog signals Connectors ������������������������������������� 1 female RJ-45 Maximum resol
Reference Information, cont’d Mounting Rack mount ������������������������ Yes, with optional 1U, 9.5" deep rack shelf (RSU 129, #60-190-01 or RSB 129, 60-604-01) or 1U, 6" deep rack shelf (RSU 126, #60-190-10 or RSB 126, 60-604-10) Furniture mount ���������������� Yes, with optional Under-Desk Mounting Kit (MBU 125, #70-077-01) Enclosure type ������������������������������� Metal Enclosure dimensions ������������������� 1.7" H x 8.7" W x 6.0" D (1U high, half rack wide) (4.3 cm H x 22.1 cm W x 15.
Reference Information, cont’d Cables N Enhanced Skew-Free™ A/V UTP cables are not recommended for Ethernet/LAN applications. Enhanced Skew-Free™ A/V cable Part number Enhanced Skew-Free A/V cable (cut, various lengths) 26-569-xx Enhanced Skew-Free A/V 1000’ (Bulk) (non-plenum) 22-141-03 Plenum enhanced Skew-Free A/V 1000’ (Bulk) 22-142-03 Connectors Connector A-6 Part number CAT 6 jack (black), qty. 10 100-476-01 CAT 6 jack (red), qty. 10 100-477-01 CAT 6 jack (blue), qty.