User`s manual

IRCM-DV+ • Quick Start Guide
ADBC EADBC E
MLC
IR
/
RCM
port
ABCD
IR
/
RCM
Control Module
C
C
+12VDC
Control signal (IRCM)
Ground ( )
B
B
A
A
To Another
Control
Module
Total distance from MLC to the farthest
control module: 150' (45.7 m) max.
C
B
A
CAUTION
Installation and service must be performed by authorized
personnel only. See “UL Requirements”, page 2-2.
The MediaLink
Controller (MLC) to which the IRCM-DV+
is connected must have MLC firmware version 1.04 or
higher in order to work with the IRCM-DV+. To set up the
IRCM-DV+ you must use MediaLink Control Software
version 2.0 or higher.
Step 1
Turn the equipment off and disconnect the equipment from the
power source.
Step 2
Install an electrical box or mud ring and cables. Use cable clamps
to hold cables in place for strain relief. Trim back or insulate exposed
cable shields with heat shrink to prevent short circuits.
Step 3
Set the DIP switches on each control module’s circuit board. For the
IRCM-DV+ select
ON
12
ON
12
ON
12
ON
12
1 and 2 down (off) =
address 0, control module #1&2
1 up (on), 2 down (off) =
address 1, control module #1&2
1 down (off), 2 up (on) =
address 2, control module #3&4
1 up (on), 2 up (on) =
address 3, control module #3&4
or
Step 4
Attach the IRCM-DV+ control module(s) to the Extron faceplate(s)
or AAP wallplate(s). See page 2-2 in this manual.
Step 5
Connect the IRCM-DV+ to the MLC,
and connect any other control
modules to each other (if
applicable) and to the
IRCM-DV+. See the
diagram below
and see pages
2-4 and 2-5.
Quick Start Guide — IRCM-DV+
QS-1