User`s manual

SCP 150 • Remote Communication
SCP 150 • Remote Communication
Remote Communication, cont’d
3-8 3-9
Command/response table for special function SIS commands (continued)
Command ASCII Command Response
X?
and
Y?
values
(host to SCP) (SCP to host) and additional descriptions
Read FPC lamp
Y?
* 51# Lmp
Y?
*
X?
Indicates the LED color of the selected
button.
Volume LED control
FPC volume LED control
X?
*
Y?
* 52# Vlmp
Y?
*
X? X?
LED blinking
Y?
LED selected:
order:
0 = off 0 = no LED
1 = bottom 1 = bottom LED
2 = blink on 2 = LED 2
3 = blink off 3 = LED 3
4 = chase up 4 = LED 4
5 = chase down 5 = LED 5
Read volume LED status
Y?
* 52# Vlmp
Y?
*
X?
Command/response table for special function SIS commands
Command ASCII Command Response
X?
and
Y?
values
(host to SCP) (SCP to host) and additional descriptions
Switch responses
Button press on front panel or remote (None) SwPrs *
X?
X?
is the switch number for the function
or button that was pressed. There are 11
options available (1-11). See the Switch/
Function Button Table, later in this chapter,
for these values.
Button release on front panel (None) SwRls *
X?
X?
is the function switch number or
button that was pressed ( 11 options). See
the Switch/Function Button Table for the
functions associated with the switches.
Front panel button LED control
FPC lamp control
X?
*
Y?
* 51# Lmp
Y?
*
X?
X?
is the LED state:
Y?
is the button:
0 = all LEDs off 0 = no button
1 = green LED on 1 = projector on
2 = red LED on 2 = projector off
3 = green and red 3 = function button 1
LEDs on (Button 4 = function button 2
lights amber.) 5 = function button 3
4 = slow blink green 6 = input button 1
5 = slow blink red 7 = input button 2
6 = slow blink amber 8 = input button 3
7 = fast blink green 9 = input button 4
8 = fast blink red 10 = input button 5
9 = fast blink amber 11 = input button 6