Specification

2.4 SUPPORT LEG ASSEMBLIES
a. ENGINEERING
1. All support assemblies shall be designed to support the ramp and platform sections
specified in sections 2.2 and 2.3.
2. Support assemblies shall be designed to hold the support tubes and legs vertical in all
locations.
3. Support tubes and legs shall have a minimum wall thickness of .094”.
b. MATERIALS
1. Support assemblies shall be constructed of aluminum alloys 6005-T5 or 6061-T6 with
polymer feet.
2. All fasteners shall be grade 5 strength or higher with zinc plated or zinc chromate finish.
c. DESIGN
1. Support tubes and legs shall be adjustable for variations in height.
2. All aluminum brackets shall be supplied for attachment of the ramps and/or platforms to
the proper support tube or leg.
3. All legs shall have a 7.375” x 7.375(minimum) square polymer foot.
2.5 HANDRAILS
a. MATERIALS
1. Handrails shall be all aluminum construction from alloys 6005-T5 OR 6061-T6.
b. DESIGN AND FABRICATION
1. Handrails shall be provided along both sides of ramp segments. The inside handrail on turn
platforms and dogleg ramps shall always be continuous. Gripping surfaces shall be
continuous, without interruption by newel posts, other construction elements, or
obstructions.
2. Handrails shall be 1½ diameter.
3. The top of the handrail gripping surface shall be mounted between 30” and 36” above the
ramp surface, and the top of the intermediate rail, when present, shall be mounted
between 18” and 22” above the ramp surface.
4. All handrail tubes shall be deburred and all sharp edges removed from gripping surfaces.
5. All handrails shall be supplied with brushed, architectural finish (optional powder coat finish
available).
6. All platform handrails shall include a 1 ½” x 2” curb located 1 ½” to 2 ½” above the platform
deck except the Vertical Picket Handrail.
2.6 VERTICAL AND HORIZONTAL PICKETS (OPTIONAL)
a. MATERIALS
1. Pickets shall be all aluminum construction from alloys 6005-T5 OR 6061-T6.
b. DESIGN AND FABRICATION
1. Pickets shall be provided along both sides of ramp segments and all sides of platforms
except where ramps attach.
2. Pickets shall be spaced so no gap exceeds 4”.
3. Pickets shall be provided with handrails which meet the same requirements as Section 2.5.
4. Pickets shall be either 1” square (vertical) or 1½” diameter (horizontal).
5. Pickets shall be supplied with brushed, architectural finish or mill finish (optional
powder coat finish available).